Page 50 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
Stranded conductor test, 8 mm insulation removed
N/A
No contact between live parts and accessible metal
parts and, for class II constructions, between live
parts and metal parts separated from accessible
metal parts by supplementary insulation only
N/A
26.6
Terminals for type X attachment and for connection
to fixed wiring suitable for connection of conductors
with required cross-sectional area according to
table 13; rated current (A); nominal cross-sectional
area (mm²) (IEC 60335-1/A2) .................................. :
Type Y attachment. N/A
Terminals only suitable for a specially prepared cord
N/A
26.7
Terminals for type X attachment accessible after
removal of a cover or part of the enclosure
Type Y attachment. N/A
26.8
Terminals for the connection to fixed wiring, including
the earthing terminal, located close to each other
Not a permanently connected
appliance.
N/A
26.9
Terminals of the pillar type constructed and located
as specified
No such terminal. N/A
26.10
Terminals with screw clamping and screwless
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for
screw terminals
Not used. N/A
Pull test of 5 N to the connection
N/A
26.11
For type Y and Z attachment: soldered, welded,
crimped and similar connections may be used
Type Y attachment. P
For class II appliances: the conductor so positioned
or fixed that reliance is not placed on soldering,
welding or crimping alone
N/A
For class II appliances: soldering, welding or
crimping alone used, barriers provided, clearances
and creepage distances satisfactory if the conductor
becomes free
N/A
27 PROVISION FOR EARTHING
27.1
Accessible metal parts of class 0I and I appliances,
permanently and reliably connected to an earthing
terminal or contact of the appliance inlet
Earthing terminal is reliably
fixed with a screw having a
washer on a metal part.
P
Earthing terminals not connected to neutral terminal
Not connected to neutral
terminal.
P
Class 0, II and III appliance have no provision for
earthing
Class I appliance. N/A
Safety extra-low voltage circuits not earthed, unless
protective extra-low voltage circuits
Not earthed. P
27.2
Clamping means adequately secured against
accidental loosening
Adequately secured against
accidental loosening.
P