Instruction manual

Page 58 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
However, glow-wire test not carried out on parts of
material classified as having a glow-wire flammability
index of at least 850 °C according to IEC 60695-2-12
(IEC 60335-1/A2)
N/A
Glow-wire flammability index only used if in specified
range of thickness (IEC 60335-1/A2)
N/A
Glow-wire test not carried out on small parts comply
with needle-flame test of annex E or on small parts
of material classified as V-0 or (IEC 60335-1/A2)
No small parts. N/A
V-1 according to IEC 60695-1-10 (IEC 60335-1/A2)
N/A
Classified V-0 or V-1 material only used if in
specified range of thickness (IEC 60335-1/A2)
N/A
Test as specified for an interposed shielding material
(IEC 60335-1/A2)
N/A
30.2.3.2
Parts of non-metallic material supporting
current-carrying connections, and (IEC 60335-1/A2)
P
parts of non-metallic material within a distance of
3 mm, (IEC 60335-1/A2)
P
subjected to glow-wire test of IEC 60695-2-11
Tested as this clause. P
However, glow-wire test not carried out on material
having a glow-wire ignition temperature according to
IEC 60695-2-13 of at least:
Not applicable. N/A
Glow-wire test of IEC 60695-2-11, the temperature being:
- 775 °C, for connections carrying a current
exceeding 0,2 A during normal operation
N/A
- 675 °C, for other connections
N/A
Glow-wire ignition temperature only used if in
specified range of thickness (IEC 60335-1/A2)
N/A
Test as specified for an interposed shielding material
(IEC 60335-1/A2)
N/A
When glow-wire test of IEC 60695-2-11 carried out, temperatures are:
- 750 °C, for connections carrying a current
exceeding 0,2 A during normal operation
Checked with a severity of
750°C.
P
- 650 °C, for other connections
N/A
If a flame persists longer than 2 s during test, then
these parts and adjacent parts further subjected to
needle-flame test of annex E, unless
(IEC 60335-1/A1 corr.1)
N/A
material is classified as V-0 or V-1 according to
IEC 60695-11-10 (IEC 60335-1/A2)
N/A
Classified V-0 or V-1 material only used if in
specified range of thickness (IEC 60335-1/A2)
N/A