Instruction manual

Page 64 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
15.3
Applicable for full disconnection and
micro-disconnection
N/A
17 Endurance
Compliance is checked on three separate appliances
or switches
N/A
For 17.2.4.4, the number of cycles is 10 000, unless
otherwise specified in 24.1.3 of the relevant part 2 of
IEC 60335
N/A
Switches for operation under no load and which can
be operated only by a tool and switches operated by
hand that are interlocked so that they cannot be
operated under load, are not subjected to the tests
N/A
Subclause 17.2.2 and 17.2.5.2 are not applicable
N/A
The ambient temperature during the test is that
occurring in the appliance during the test of
clause 11 in IEC 60335-1
N/A
Temperature rise of the terminals not more than
30 K above the temperature rise measured in
clause 11 of IEC 60335-1
N/A
20
Clearances, creepage distances, solid insulation and coatings of rigid printed board
assemblies
This clause is applicable to clearances and creepage
distances for functional insulation, across full
disconnection and micro-disconnection, as stated in
table 24
N/A
J
ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards carried out in accordance with
IEC 60664-3 with following modifications (IEC 60335-1/A2):
5.7 Conditioning of the test specimens (IEC 60335-1/A2)
When production samples used, three samples of
printed circuit board are tested (IEC 60335-1/A2)
No coated PCBs. N/A
5.7.1 Cold (IEC 60335-1/A2)
Test carried out at -25 °C (IEC 60335-1/A2)
N/A
5.7.3 Rapid change of temperature (IEC 60335-1/A2)
Severity 1 is specified (IEC 60335-1/A2)
N/A
5.9 Additional tests (IEC 60335-1/A2)
Subclause not applicable (IEC 60335-1/A2)
N/A