TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
K
ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is
extracted from IEC 60664-1
Considered. P
Overvoltage category is a numeral defining a
transient overvoltage condition
Considered. P
Equipment of overvoltage category IV is for use at
the origin of the installation
N/A
Equipment of overvoltage category III is equipment
in fixed installations and for cases where the
reliability and the availability of the equipment is
subject to special requirements
N/A
Equipment of overvoltage category II is energy
consuming equipment to be supplied from the fixed
installation
Overvoltage category II. P
If such equipment is subjected to special
requirements with regard to
reliability and availability,
overvoltage category III applies
N/A
Equipment of overvoltage category I is equipment for
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low
level
N/A
L
ANNEX L (INFORMATIVE)
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Sequences for the determination of clearances and
creepage distances
Considered. P
M
ANNEX M (NORMATIVE)
POLLUTION DEGREE
The information on pollution degrees is extracted
from IEC 60664-1
Considered. P
Pollution
The microenvironment determines the effect of
pollution on the insulation, taking into account the
microenvironment
P
Means may be provided to reduce pollution at the
insulation by effective enclosures or similar
P
Minimum clearances specified where pollution may
be present in the microenvironment
P