Page 67 of 100 Report No. 255837
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement Test Result Verdict
O
ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to
heat and fire (IEC 60335-1/A2)
Considered. P
P
ANNEX P (INFORMATIVE)
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 0I appliances having a rated voltage
exceeding 150 V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE
Modifications may also be applied to class I appliances having a rated voltage
exceeding 150 V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor
5 General conditions for the tests
5.7
The ambient temperature for the tests of clauses 11
and 13 is 40
+3
0
°C
Not applicable. N/A
7 Marking and instructions
7.1 The appliance marked with the letters WDaE
N/A
7.12
The instructions state that the appliance is to be
supplied through a RCD having a rated residual
operating current not exceeding 30 mA
N/A
The instructions state that the appliance is
considered to be suitable for use in countries having
a warm damp equable climate, but may also be used
in other countries
N/A
11 Heating
11.8 The values of table 3 reduced by 15 K
N/A
13 Leakage current and electric strength at operating temperature
13.2
The leakage current for class I appliances not
exceeding 0,5 mA
N/A
15 Moisture resistance
15.3 The value of t is 37 °C
N/A
16 Leakage current and electric strength
16.2
The leakage current for class I appliances not
exceeding 0,5 mA
N/A
19 Abnormal operation
19.13
The leakage current test of clause 16.2 is applied in
addition to the electric strength test of 16.3
N/A