CONFIDENTIAL
Signal: 1024 x 768 (68 kHz/85 Hz)
Display image: Dont care
Contrast: Minimum
Brightness: Minimum
Limit: 26.0 kV ± 0.3 kV
Measure the high voltage level at the anode cap.
High voltage should be within the limit as above.
4-2-2 CENTER RASTER
Adjust SW401 so that the back raster comes to the
center when you apply basic mode for 17.
4-2-3 Centering
Centering means to position the center point of
the display in the middle of the display area.
Horizontal size and position and vertical size and
position control the centering of the display.
Adjust the horizontal size and vertical size to their
optimal settings: 312 mm (H) x 234 mm (V).
Adjust the horizontal position and vertical
position to 5.0 mm of the center point of the
screen.
|A-B| 5.0 mm. |C-D| 5.0 mm.
Figure 4-3. Centering
* In Softjig window, Geometry has to be
selected for GD adjustment.
4-2-3 (a) HORIZONTAL SIZE ADJUSTMENT
CONDITIONS
Scanning frequency: 68 kHz/85 Hz
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Click Standard Dump on the right Menu in the
general field.
Use control bar after selecting size B+ in the left
Menu to adjust the horizontal size of the display,
Pattern to 312mm(Tolerance : ±4mm.)
Run the All Mode save in the Right Menu.
Caution : Do not Run the All mode Save at the
other scannig times except for 1024x768
(68kHz/85Hz).
4-2-3 (b) VERTICAL SIZE ADJUSTMENT
CONDITIONS
Scanning frequency: 68 kHz/85 Hz
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Use control bar after selecting “V-SIZE” in left
menu to adjust the vertical size of the display
pattern to 234 mm.(Tolerance: ± 4 mm.)
4-2-3 (c) HORIZONTAL POSITION ADJUSTMENT
CONDITIONS
Scanning frequency: 68 kHz/85 Hz
Display image: Crosshatch pattern
Use control bar after selecting H-POSITION in
left menu to center the horizontal image on the
raster.
4-2-3 (d) VERTICAL POSITION ADJUSTMENT
CONDITIONS
Scanning frequency: 68 kHz/85 Hz
Display image: Crosshatch pattern
Use control bar after selecting V-POSITION in
left menu to center the vertical image on the
raster.
4-2-4 Linearity
Linearity affects the symmetry of images as they
appear on the screen. Unless each row or column
of blocks in a crosshatch pattern is of equal size,
or within the tolerances shown in Tables 4-2 and
4-3, an image appears distorted, elongated or
squashed.
Table 4-1. Standard Modes Linearity:
1024x768/85Hz
4-2 Display Control Adjustments
4-2-1 HIGH VOLTAGE
C
A
DISPLAY AREA
EDGE OF BEZEL
B
D
4 : 3
Horizontal: 20.9~23.1
Vertical : 20.9~23.1
Standard Modes Linearity
Each block (8 %)
Difference between
adjacent blocks (4 %)
Horizontal: Less than 0.88 mm
Vertical : Less than 0.88 mm