Product specifications

3-2 Function Description
3-2-1 Cooling operation mode
3-2 Samsung Electronics
FANCOOL
POWER / MODE
°C
Hour
Remote control sensor
Temperature/Timer settings
Temperature indicator
Timer indicator
POWER/MODE BUTTON
Operating mode indicator
The compressor is turned on and off according to the ambient temperature and set temperature.
1. Compressor on and off control
• Compressor on and off control according to the ambient temperature.
*
The compressor is turned off when "ambient temperature = set temperature -1˚C"
*
The compressor is turned on when "ambient temperature = set temperature +1˚C"
2. Default value after power reset set temperature = 18˚C
FAN SPEED = HIGH
3. Set temperature indicating (setting) range : 1˚C interval from 18˚C to 30˚C.
3-2-2 Fan operation mode
1. If "Fan operation mode" signal is received from remocon.
the compressor is immediately turned off and only fan motor is operated at set blowing speed.
it changes such as "HIGH LOW HIGH"( if Fan speed is selected).
2. The initial FAN speed is set to "HIGH".
3. The set temperature can not be indicated and set.
AW126JB-1 6/27/98 10:38 AM Page 6