Instruction manual

Page 14 of 97 Report No. 236145
TRF No. IEC60335_2_40F
IEC 60335-2-40
Clause Requirement – Test Result Verdict
Additional warning symbol (flame symbol: B.3.2 of
ISO 3864) placed on nameplate of unit near
declaration of refrigerant type and charge
information. Perpendicular height be at least 10 mm,
and symbol need not be in colour
(IEC 60335-2-40/A1)
N/A
Following warning also applied to appliance when
flammable refrigerant employed.
WARNING
Appliance shall be installed, operated and stored in a
room with a floor area larger than ‘X’ m² (only applies
to appliances that are not fixed appliances)
(IEC 60335-2-40/A1)
N/A
Not fixed appliances, minimum room size X specified
on appliance. X in marking determined in m² by
procedure described in paragraph 2 of annex GG for
unventilated areas and X in marking be 4 if
refrigerant charge of appliance is less than m
1
(see
annex GG, paragraph 1.1) (IEC 60335-2-40/A1)
N/A
Maximum allowable pressure for low-pressure side
and high-pressure side marked on product
(IEC 60335-2-40/A1)
N/A
If not already visible when accessing service port
and if service port provided, service port marked to
identify type of refrigerant. If refrigerant is flammable,
symbol B.3.2 of ISO 3864, be included, without
specifying the colour (IEC 60335-2-40/A1)
N/A
7.2 Warning for stationary appliances for multiple supply
P
Warning placed in vicinity of terminal cover
P
7.3 Range of rated values marked with the lower and
upper limits separated by a hyphen
220 – 240 V P
Different rated values marked with the values
separated by an oblique stroke
N/A
7.4 Appliances adjustable for different rated voltages,
the voltage setting is clearly discernible
Not adjustable for different
rated voltages.
N/A
7.5 Appliances with more than one rated voltage or one
or more rated voltage ranges, marked with rated
power input or rated current for each rated voltage or
range, unless
Single rated voltage range of
220 – 240 V.
N/A
the power input is related to the mean value of the
rated voltage range
P
Relation between marking for upper and lower limits
of rated power input or rated current and voltage is
clear
Single rated voltage range of
220 – 240 V.
N/A
power input is related to the arithmetic mean value of
the rated voltage range (IEC 60335-1/A2)
P
7.6 Correct symbols used
Correct symbols are used. P