Installation requirements
English14
Alcove or closet installations
WARNING
The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or
closet.
No other fuel-burning appliance should be installed in the same closet as the dryer.
Place the dryer at least 18 inches (460 mm) above the floor for garage installation.
Minimum clearances between the dryer and adjacent walls or other surfaces:
Sides 1 in. (25 mm) Rear 5.9 in. (150 mm)
Top 21 in. (533 mm) Closet front 2 in. (51 mm)
If both the washer and a dryer are installed in the same location, the front of the alcove or closet must have
two unobstructed air openings for a combined minimum total area of 72 in.
2
(465 cm
2
).
Installation with pedestal
A
CB D
F
E
A 52.9 in. (1343 mm) D 27 in. (686 mm)
B 32.5 in. (825 mm) E 46.9 in. (1192 mm)
C 5.9 in. (150 mm) F 52.2 in. (1326 mm)