User Manual
Table Of Contents
English
Installation requirements
English14
Alcove or closet installations
WARNING
• The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or
closet.
• No other fuel-burning appliance should be installed in the same closet as the dryer.
• Place the dryer at least 18 inches (460 mm) above the floor for garage installation.
Minimum clearances between the dryer and adjacent walls or other surfaces:
Sides 1 in. (25 mm) Rear 5.9 in. (150 mm)
Top 21 in. (533 mm) Closet front 2 in. (51 mm)
If both the washer and a dryer are installed in the same location, the front of the alcove or closet must have
two unobstructed air openings for a combined minimum total area of 72 in.
2
(465 cm
2
).
Installation with pedestal
A
CB D
F
E
A 52.9 in. (1343 mm) D 27 in. (686 mm)
B 32.5 in. (825 mm) E 46.9 in. (1192 mm)
C 5.9 in. (150 mm) F 52.2 in. (1326 mm)
Untitled-5 14 2021-05-25 5:20:36