Security Camera User Manual

English – 13
ENG
Installation
DIP SWITCH SETUP
Before you install the camera, you should set the DIP
switches to confi gure the camera ID, Baud rate, and
communication protocol.
Camera ID Setup
ID number of camera is set using binary number.
The example is shown bellow.
Pin 12345678
ID Value 1 2 4 8 16 32 64 128
ex) ID=5
ex) ID=10
on
off
off
on
on
off
off
on
off
off
off
off
off
off
off
off
The range of ID is 0~255. Factory default of
Camera ID is 1.
If you want to control a certain camera, you must
match the camera ID with Cam ID setting of DVR
or Controller.
Communication Protocol Setup
Select the appropriate Protocol with DIP switch
combination.
Switch State
Protocol
Pin1 Pin2 Pin3 Pin4
OFF OFF OFF OFF Auto Protocol
ON OFF OFF OFF Pelco-D
OFF ON OFF OFF Pelco-P
ON ON OFF OFF Samsung
If you set the protocol as Auto Protocol, camera
will automatically recognize the kind of Protocol.
Auto Protocol supports Pelco-D and Samsung Protocol.
If you want to control using DVR or system
keyboard, their protocol must be identical to
camera. Otherwise, you can not control the camera.
If you changed camera protocol by changing DIP S/W,
the change will be effective after you reboot the camera.
Factory default of protocol is “Auto Protocol
Communication Baud rate Setup
Select the appropriate Baud rate with DIP switch
combination.
Switch State
Protocol
Pin5 Pin6 Pin7
OFF OFF OFF 2400 BPS
ON OFF OFF 4800 BPS
OFF ON OFF 9600 BPS
ON ON OFF 19200 BPS
OFF OFF ON 38400 BPS
Factory default of Baud rate is “9600 BPS”
123456
ON
ON
78
123456
ON
ON
78
Protocol
Buad Rate
Auto Select
RS-485
Terminate
ID Setting (1~255)