A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50
amp range cord is not recommended but if used, it should be marked for use with
nominal 1
3
8" diameter connection openings. Care should be taken to center the
cable and strain relief within the knockout hole to keep the edge from damaging the
cable.
Because range terminals are not accessible after the range is in position, a flexible
service conduit or cord must be used.
NOTE If the power connection is plugged in improperly, the following
message appears on the display.
• LCD, PMOLED : Wire installation fail
• LED : bAd LinE
Reconnect the power connection properly, and the message disappears.
ALL NEW BRANCH-CIRCUIT CONSTRUCTIONS, MOBILE HOMES,
RECREATIONAL VEHICLES, AND INSTALLATIONS WHERE LOCAL
CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL,
REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD.
STEP 2. ACCESSING THE POWER CORD CONNECTION
Loosen and then remove the rear access cover screw with a screwdriver. Remove
the rear access cover by pull right and then out. The terminal block will then be
accessible.
Access cover
Terminal block
English - 9