NX58M6630S*
BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP)
Burner Location BTU Rate Orice Size [mm]
RF 14,500 1.12
LF 11,500 1.04
RR 4,000 0.62
LR 7,500 0.83
CTR 7,500 0.83
BROIL 11,500 1.02
BAKE 15,000 1.15
BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP)
Burner Location BTU Rate Orice Size [mm]
RF 18,000 1.94
LF 16,000 1.88
RR 5,000 1.01
LR 9,500 1.40
CTR 10,000 1.40
BROIL 13,500 1.64
BAKE 18,000 1.90
Step 3. Convert to LP gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 52 in the User
Manual to contact a qualied service technician.
The conversion process should only be performed by a qualied LP gas installer.
Conversion instructions and LP orices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orices to be changed (5 surface burners
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orices must be left with the consumer, including the instructions and
retrot sizes and orice indication.
NX58M6650W*
BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP)
Burner Location BTU Rate Orice Size [mm]
RF 14,500 In 0.46 / Out 0.74 (2 pcs)
LF 11,500 1.04
RR 4,000 0.62
LR 7,500 0.83
CTR 7,500 0.83
BROIL 11,500 1.02
BAKE 15,000 1.15
BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP)
Burner Location BTU Rate Orice Size [mm]
RF 20,000 In 0.85 / Out 1.29 (2 pcs)
LF 15,000 1.78
RR 5,000 1.01
LR 9,500 1.40
CTR 10,000 1.40
BROIL 13,500 1.64
BAKE 18,000 1.90
NX5000M_NX58M6650WS_AA_DG68-00992A-01_EN+MES+CFR.indb 22 2017-08-16  2:38:34