Installation Guide

28 English
Installation instructions
Installation instructions
Locking screw
The shutters are located at the base of the
burner manifolds near the back oven wall.
To adjust the shutter, loosen the locking
screw and rotate the shutter towards the
open or closed position as needed. If ames
are lifting off the burner ports, gradually
reduce the air shutter opening until the
ames are stabilized.
If ames are too yellow and/or too large,
gradually increase the air shutter opening
until the ames have approximately a 1-in
blue cone.
NOTE
If the range is set up for natural gas, the
ames should burn with soft blue ames
prevailing. If the range is set up for LP gas,
small yellow tips at the end of the cones are
normal.
Locking
screw
After the ames are adjusted properly, shut
off the oven, retighten the locking screws,
replace the oven bottom and racks, and
close the oven door.
Adjusting the oven burner air adjustment shutters
Air
adjustment
shutter
All oven burners have an air adjustment
shutter. The purpose of the shutter is to
regulate the ow of air to the ames.
Properly adjusted ames should burn
steadily with approximately 1-in of blue
cone. The ames should never extend
past the edge of the burner bafes. Even
though these are preset at the factory, they
should be checked and, if needed, adjusted
periodically to ensure efcient operation.
To check and adjust the oven burner air adjustment shutters:
1. Open the oven door.
2. Remove the oven racks.
3. Remove the oven oor.
4. Press the Bake pad, then the START pad.
5. After the oven has lit, visually check the ames coming out of the upper and
lower burners. If adjustment is needed, carefully adjust the air adjustment
shutters.
NX5000M_NX58M6650WS_AA_DG68-00992A-01_EN+MES+CFR.indb 28 2017-08-16  2:38:36