Installation Guide

English 21
Installation instructions
2. Install male 0.5-in (1.3-mm) are union adapter to the 0.5-in (1.3-mm) NPT
internal thread at the regulator inlet. Use a backup wrench on the regulator
tting to avoid damage.
When installing the range from the front, remove the 90 ° elbow for easier
installation.
3. Install male 0.5-in (1.3-mm) or 0.75-in (1.9-mm) are union adapter to the
NPT internal thread of the manual shut-off valve, taking care to back up the
shut-off valve to keep it from turning.
4. Connect exible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the
off position and turn on the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in the system.
WARNING
Do not use a ame to check for gas leaks to prevent death, personal injury,
explosion, and/or re hazard.
When using test pressures greater than 1/2 psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of 1/2 psig or less to test the gas
supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Adapter
Flex
Connector
(6-ft max.)
Tubing Line to
Cooktop Control
Manifold
Pressure
Regulator
Adapter
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Tubing Line to
Oven Burner
Control Valve
Gas Flow into Range
NOTE
If your area requires a rigid pipe hookup,
contact a qualied installer, service agency,
or gas supplier.
NOTE
The gas shut-off valve should be installed
in an accessible location in the gas piping,
external to the appliance, for the purpose
of turning on or shutting off the gas to the
appliance.
NX5000M_NX58M6650WS_AA_DG68-00992A-01_EN+MES+CFR.indb 21 2017-08-16  2:38:34