User Manual

English 5
Installation requirements
Single Oven Under counter
D
A
F
E
B
G
C
H
01
02
01 See built-in oven installation for
complete installation instructions.
See label on top of approved built-in
oven models.
02 Refer installation Manual of OVEN.
Size
A Min. 3
3
/4” (9.5 cm)
B 4” (10.1 cm)
C Min. 28
1
/2”/ Max. 28
5
/” (Min. 72.4 cm / Max. 72.7 cm)
D Min. 1”/ Max. 1
1
/4” (Min. 2.5 cm / Max. 3.2 cm)
E Min. 27
1
/4”/ Max. 27
3
/8” (Min. 69.2 cm / Max. 69.5 cm)
F 24” (61 cm)
G Min. 22” (Min 55.9 cm)
H Max. 9
1
/2” (Max. 24.1 cm) – Junction Box
IMPORTANT:
If installing a range hood or microwave hood combination above the cooktop,
follow the range hood or microwave hood combination installation instructions for
dimensions and clearance above the cooktop surface.
G
F
A
C
E
E
D
B
Cooktop
Rear Wall
Countertop
Junction box
Minimum distance to
combustible side wall above
countertop (both sides)
NZ30K******(30”) NZ36K******(36”)
A 28
1
/2” - 28
11
/16” (724 mm - 728 mm)
33
7
/8” - 34” (860 mm - 864 mm)
B
19
9
/
16
” - 19
5
/
8
” (497.4 mm - 499.4 mm)
19
1
/
8
” - 19
3
/
16
” (485.6 mm - 487.6 mm)
C Min 1
1
/8” (28 mm). Between cutout and the wall behind the cooktop
D Min 1
1
/2” (38 mm). From front edge of cutout and front edge of countertop
E Min 1” (26 mm). Distance nearest left and right side combustible surface
above cooktop.
F Junction box or outlet 10” (254 mm) maximum from right-hand side of
cabinet
G Junction box or outlet 15” (381 mm) minimum from bottom of countertop
Radiant Install_NZ30K7570R_DG68-00825A-07_EN+MES+CFR.indb 5 11/22/2019 2:45:12 PM