User Manual

English _13
! INSTALLATION & CONNECTION
Install lens module (SLA-T1080FA)
1. Drill a hole which the lens is passed through at the location where you want to
install it.
J
`
Hole size (inner diameter): Ø30 ± 2mm
(If the size of the hole is outside of this range, the installation may fail.)
2. After inserting the lens module into the hole, fix the lens module using the supplied nut (M27).
3. Fix the cable separately. (Within 1m from the lens module)
Install lens module (SLA-T2480A/SLA-T4680A)
1. Use two screws provided or remove protective film to use the double-
sided tape on the bottom side of the lens module bracket to install the
lens module bracket.
J
`
Remove foreign substances on the target object before attachment.
2. Push the lens module into the bracket.
3. Considering the direction of monitoring, adjust the lens to make it face
the desired direction.
4. Fasten the screw next to the bracket and fix the lens direction.
5. After installation, pull the cable. Make sure that the lens module does
not move by fixing it to the bracket with the cable tie.
6. Organize the cable separately (within 1m from the lens module).