SH12YA1 SH12UA1 SH12YA9 Split-type Room Air Conditioner (Cool and Heat) Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción) Condizionatore d’aria per ambienti ad unità Separate (Raffreddamento e Riscaldamento) Aparelho de ar condicionado tipo Split (Refrigeração e Aquecimento) Climatiseur de type Séparé (Refroidissement et Chauffage) Geteilte raumklimaanlage (Kühlen und Wärmen) E S I P F D DB68-01374A(4) ENGLISH ESPAÑOL ITALIANO Indoor Unit DEUTSCH OWNER’S INSTRUCTIONS MANUAL DE I
Safety Precautions The following safety precautions must be taken when using your air conditioner. 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist. 3 Do NOT insert anything between the air flow blades, as the inner fan may be damaged and you may be hurt.
ENGLISH Contents ◆ PREPARING YOUR AIR CONDITIONER ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 ■ Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . .6 ■ Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 ■ Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . .
View of the Unit The design and shape are subject to change according to the model.
ENGLISH Outdoor Unit Air Inlet(Rear) Air Outlet Connection Valve (Inside) E-5
Remote Control - Buttons and Display Remote control transmission indicator Operating mode ( AUTO, COOL, DRY, FAN, HEAT) Temperature setting Turbo mode Sleep mode Fan speed Mode selection button (AUTO, COOL, DRY, FAN, HEAT) Temperature adjustment buttons Turbo/Sleep mode selection button Air flow direction Fan speed adjustment button Swing button On Timer setting On Timer button Off Timer setting Off Timer button Battery discharge indicator On/Off & Timer Set/Cancel button E-6
ENGLISH Getting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s features. The booklet is organized as follows.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : ◆ You purchase the air conditioner ◆ The remote control does not work correctly Note E-8 ◆ ◆ ◆ ◆ Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
ENGLISH Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The OPERATION indicator on the indoor unit comes on. ◆ The air conditioner starts up in the mode selected when the unit was last used.
Cooling Your Room You must select the Cool mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The OPERATION indicator on the indoor unit comes on. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
ENGLISH Heating Your Room You must select the Heat mode if you wish to adjust the: ◆ Heating temperature ◆ Fan speed when heating 1 If necessary, press the Result: IMPORTANT 2 (On/Off) button. ◆ The OPERATION indicator on the indoor unit comes on. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool or heat your room as quickly as possible. Example : You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the Result: 2 Press the Result: 3 E-12 button.
ENGLISH Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the Result: ◆ The OPERATION indicator on the indoor unit comes on. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. IMPORTANT 2 (On/Off) button.
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the Result: 2 ◆ The OPERATION indicator on the indoor unit comes on. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. If the is not displayed at the top of the remote control, press the MODE button on the remote control one or more times until it appears. Result: Note 3 (On/Off) button.
ENGLISH Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the SWING button one or more times as required. Result: The outer blade is adjusted vertically. RECOMMENDATION 2 Adjust the blade to face... Cooling Heating Upwards. Downwards.
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the ON TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. Result: 2 Press the ◆ Each time you press ON TIMER button: - The time is adjusted by 0.5 hour to 5 hours, by 1 hour from 6 hours to 24 hours.
ENGLISH Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the OFF TIMER button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. Result: 2 ◆ Each time you press OFF TIMER button: - The time is adjusted by 0.5 hour to 5 hours, by 1 hour from 6 hours to 24 hours.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of six hours. Note If you wish to switch the unit off at a specific time, refer to page 17. 1 Make sure that you have selected either COOL or HEAT mode. 2 Press the button one or more times until remote control. ◆ The indoor unit beeps. ◆ The SLEEP indicator on the indoor unit lights up.
ENGLISH Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors. If the temperature of the outside air drops, the air conditioner will heat less. If you find that the room is not warm enough, use an additional heating appliance.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leakage or some other malfunction may happen if the heat exchanger freezes.
ENGLISH Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not operate at all ◆ Check that the breaker used for the air conditioner is switched on. ◆ Check that the OPERATION indicator on the indoor unit is on; if necessary press the (On/Off) button on the remote control.
Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 1 To switch the air conditioner on, press the ON/OFF switch on the right side of the indoor unit. Result: ◆ The OPERATION indicator on the indoor unit comes on. ◆ The indoor unit beeps.
ENGLISH Technical Specifications Model Indoor unit Power Supply SH12YA1 SH12UA1 SH12YA9 220-240V~, 50Hz ◆ Package Weight Model Paper Plastic Wood SH12YA1 SH12UA1 SH12YA9 2.51kg 0.
THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: DIESE KLIMAANLAGE IST FABRIZIERT VON: ELECTRONICS Printed in Korea