WEB WEB TRANSMITTER SNS-110 Owner's Manual (Version 1.
Before You Begin This manual is the basic guide for all Web Transmitter SNS-110 users. It mainly illustrates product background, installation method, and connection through web browsers as well as GUI (Graphic User Interface) after connection. Please, familiarize yourself of the contents in this manual before using SNS-110 product. Make sure you refer to an expert when opening the outer case for the purpose of repair.
Regulation Approval Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Table of Contents Chapter 1. SNS-110 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Functions and Feature - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Names and Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 Chapter 2.
Chapter 7.
Chapter 1 SNS-110 Overview Overview SNS-110, connected to surveillance cameras or other external devices, compresses video image as motion JPEG through zip algorithm and transmits it to a remote party through network (Ethernet, cable modem). SNS-110 may be connected to maximum of 4 video images and concurrently transmits the image in a form of single screen, quadruplex screen, or automatic sequential screen.
● You can send video image files through FTP server at certain time or in regular intervals. Users can access the FTP server and search the saved video files. ● You can change the LOGO image on SNS-110 screen, or background color or font colors. Search SNS-110 to download the latest software at http://www.samsungelectronics.
Names and Function Familiarize yourself with the names and function of each part on the front and back panels, before installing SNS-110. Front View of SNS-110 1 3 4 5 6 3 4 1.CONTROL 2.F/H 3.Tx R 4.Rx R 7 8 9 10 2 Name Function ① Video In Receives input from maximum of 4 video image signals. ② Video Out (Loop Through Out) Transmit the image output to cameras or other external video-imaging devices ❈ When connected, the terminal resistance of 75Ω is automatically seized.
Rear of SNS-110 ALARM IN RS-232C R/O RX TX ETHERNET DC 5V 1 2 G 3 4 G RA RC - + - + 1 2 4 3 Name 5 6 Function ① Alarm Input(1,2,3,4) Sensor Input : 1,2,3,4 Signal GND : G Connects to maximum of 4 alarm sensors. ② R/O (Relay Out) Connected to the external device for remote control ③ RS-485(+,-) RA RC Connects to RS-485 cable and remotely regulate PAN / TILT / ZOOM / FOCUS controllers. Full Duplex : use RX and TX. Half Duplex : use TX .
Chapter 2 Installing SNS-110 Preparation and installation of SNS-110 Setting Configuration Please, familiarize yourself of the safe condition of SNS-110 installation. This product must be horizontally stabilized and not be sloped or vertically positioned. Positioning and properly centering its wiring room are crucial for its aptitude function.
Cautions in Installation Be aware of the following cautions when installing SNS-110. ● Always turn the power off before SNS-110 installation. ● Severe impact or vibration may cause malfunction. ● Avoid places with strong magnetic or electric field, or places near a radio or TV. ● Always keep the place dust-free when installing or moving SNS-110.
15Cm ● Position it in an open space with flat surface, keeping the aptitude temperature. Also, maintain the clearance between back of the main body and the wall. ● Be careful not to insert accidentally any conducting material in the ventilation space of product. ● Turn the power off and disengage the power cord from the body, when changing the circuit-protecting fuse. ● Avoid a direct ray of light, and keep the safe distance between crowded place and the product as well as its assemblies.
● Do not neglect fumes or unusual odor, which may be symptoms of malfunction. When these are identified, please instantly disconnect the power and consult to an expert from your local service center. NOTE Always use a dry cloth when cleaning this product. If the contamination is serious, please wipe it first with a neutral detergent, then with a dry cloth. Avoid using volatile material, such as alcohol, benzene, or sinner, when wiping the surface, due to potential damage on the surface.
Unpacking When you purchase SNS-110, after removing the wrap, place the product on a flat surface or where you will be installing it. Then, check if there is any missing part among the following items.
Chapter 3. Connecting to Instruments You may connect the following items with SNS-110, such as video image players (e.g., VTR, DVDP, etc.,), network devices, alarm sensors, PAN/TILT/ZOOM/FOCUS controllers, and PC-connected consoles. Caution No voltage, more than DC 2V, must be connected to the video in/output terminal 1~4. Connecting to Camera and Video Image Players (e.g., VTR, DVDP, TV) VTR, DVDP, TV OUT CAMERA 3 4 1.CONTROL 2.F/H 3.Tx R 4.
Connecting to External Instruments VTR, DVDP, TV OUT CAMERA 3 4 1.CONTROL 2.F/H 3.Tx R 4.Rx R VIDEO IN External Device SNS-110 produces the video image signal of the corresponding channel, if connected with external instruments to Video Out 1~4 (loop through BNC). The terminal resistance of 75Ω will be automatically seized by the connection with external instruments. External Device Surveillance control units : Frame Switcher, Quad Switcher, Sequential Switcher, Multi-plexer, Monitor, etc.
Connecting to Network Ethernet(10BaseT/100BaseT) ALARM IN RS-232C R/O RX TX ETHERNET DC 5V 1 2 G 3 4 G RA RC - + - + RJ- 45 Ethernet Cable(Direct) HUB INTERNET Back Bone Cable Modem ALARM IN RS-232C R/O RX TX ETHERNET DC 5V 1 2 0 3 4 0 RA RC - + - + RJ- 45 Ethernet Cable(Direct) Cable Modem Cable Network INTERNET Back Bone CMTS (Cable Modem Termination System) 17
Connecting to Alarm Sensors and External Devices ALARM IN R/O RX TX 1 2 G 3 4 G RA RC - + - + S E N S O R 1 SG S S G E N E E N ND N N D S S S O O O R R R 2 3 4 Function Alarm In Relay Out Name Alarm 1/2/3/4/G RA/RC Regular Capacity -TTL Level(5VDC) -Initial Contact Resistance, Max. : 75m§ -Max. Switching Power : 60W, 62.5VA -Max. Switching Voltage : 220VDC/125VAC -Max. Carrying Current : 2A -Contact Rating(Resistive) : 2A 30VDC/0.
Connecting to PAN/TILT/ZOOM/FOCUS Controller RXP/T/Z/F Controller 1 RX+ ALARM IN R/O RX TX RXP/T/Z/F Controller 2 1 2 G 3 4 G RA RC - + - + RX+ RXP/T/Z/F Controller 3 RX+ RXP/T/Z/F Controller 4 RX+ The RX/TX terminal of the reverse side of the SNS-110 uses the RS-442/485 interface and PAN/TILT/ZOOM/FOCUS controllers can be connected to the terminal. The PAN/TILT/ZOOM/FOCUS controllers that are supported are the following.
Connecting to RS-232C When connecting PC serial port (COM1, COM2) through RS-232C from back of SNS-110, you may select console mode of SNS-110 by using PC terminal emulation program (HyperTerminal). Control S/W from the front panel must be positioned "OFF". Caution In the console mode, if you change the existing data improperly, the system may result in serious problems.
Creating RS-232C Cable The RS-232C Cable is packed with SNS-110, and so you don’t need to make it . The wiring diagram shown below is for your information.
Creating Ethernet Cable Since the Ethernet Cable is not packed with SNS-110, the user has to purchase and use it .
Chapter 4 Setting an IP Address No information upon network is set up except Ethernet address (MAC address) in factory defaults. You must set up the IP address when installing. Caution Ethernet address (00-00-f0-XX-XX-XX) is recorded on the bottom of the product at the time of purchase. Because it may be accidentally erased, please duplicate the number and keep it somewhere else. Before You Begin (1) Confirm the Ethernet address (00-00-f0-XX-XX-XX) on the bottom of SNS-110.
Setting In Ethernet (10BaseT/100BaseT) For Windows 95/98/ME/NT/2000/XP (1) Open Dos window from network-connected PC with SNS-110. (2) Execute "arp -s". arp -s Example : arp -s 168.219.15.250 00-00-f0-ff-a1-0a (3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "arp -a". arp -a Example : arp -a Internet Address 168.219.15.249 168.219.15.
(4) Wait until you receive the normal response after executing "ping". ping Example : ping 168.219.15.250 - 110 -n 20 You must enter it. 110 -n 20 Pinging 168.219.15.250 with 32 bytes of data: Request timed out. Request timed out. No Response Request timed out. Request timed out. Reply from 168.219.15.250: bytes=110 time=1ms TTL=255 Reply from 168.219.15.250: bytes=110 time=1ms TTL=255 Reply from 168.219.15.250: bytes=110 time=1ms TTL=255 Reply from 168.219.15.
Setting in Unix (1) Execute the following instruction for network-connected Unix machines with SNS-110. (2) Execute "rarp -s". rarp -s Example : rarp -s 168.219.15.250 00:00:f0:ff:a1:0a (3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "rarp - a". rarp -a Example : rarp -a IP Address 168.219.15.249 168.219.15.
(4) See if you receive the normal response as shown below after executing "ping". ping Example : ping 168.219.15.250 PING 168.219.15.250 (168.219.15.250): 56 data bytes 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms 64 bytes from 168.
Setting with IP Installer The 'IP Installer' is an application program that supports easy setting of network parameters of SNS-110 such as IP Address, Gateway, Subnet Mask and so on. Before executing the 'IP Installer', the SNS-110 should be connected with PC through RS-232C cable. The 'IP Installer' works on Windows 95/98/ME/NT/2000/XP. ● Program Name of IP Installer : SetupWebTX_v11.exe Note You can download the 'SetupWebTX_v11.exe' at 'http://www.samsungelectronics.com'.
Note If the serial port which you select is being used by other device, you will see the following window. In this case, you have to stop the usage of serial port by other device or change the connection of SNS-110 to other serial port. (4) If the SNS-110 and PC is successfully connected through RS-232C cable, you will see the following window. (5) In obedience to the 'Comments' of the program, reset SNS-110 by pushing the 'RESET' button or by turning off and on of SNS-110.
(6) Set up or modify the network parameters, and then click the 'OK' button. (7) If the setting of network parameters succeeds, you will see the following window.
(8) After the setting of network parameters, the SNS-110 will automatically reboots. If all of the network parameters are properly set, you can connect SNS-110 with Web Browser. Note If the 'success' message window does not appear even though you wait more than 10 seconds after clicking 'OK' button, stop the program by clinking 'Cancel' button. And then, execute the "SetupWebTX_v11.exe' and follow above processes again.
Setting Other Network Information After successfully setting up the IP address in Ethernet, follow the next procedure to set up additional network information. After the previous procedure, you must set up the following information, confirmed by the network manager, to connect to network successfully. ● Gateway ● Subnet Mask ● Domain Name ● DNS (1) Open a web browser (Netscape or Explorer) from the network-connected PC or Unix machine with SNS-110 installed.
In Cable Network through Cable Modem (1) Connect according to "Connecting to Cable Modem" of Chapter 3 Connecting to Network, and turn the SNS-110 power on. (2) SNS-110 automatically receives the following information from the cable network manager by executing DHCP (Dynamic Host Configuration Protocol), if connected to cable network through a cable modem. ● IP Address ● Gateway ● Subnet Mask (3) Please confirm the auto-assigned IP Address from PC terminal emulation (HyperTerminal) connected to RS-232C.
Chapter 5 SNS-110 Log-in After successfully setting up an IP address as in Chapter 4, execute a web browser (Netscape or Explorer) from an Internet PC. Ideal Specification If your PC performance is not compatible, the image processing speed will decrease in your web browser, resulting in possible short-image. Also, incompetent PC performance may cause PC abnormal function because of PC resource parts. Therefore, use ● CPU: Pentium II more than. ● Main Memory: 64 MByte or more.
(3) If you have properly logged in, you will see the following. (4) Properly enter user name and password and click "OK" button. You should see the initial screen of Chapter 6 Application Mode. Log-in through Explorer First Time (1) If you have never logged in through Explorer, first download plug-in program from SNS-110. Then, follow the next procedure. (2) Open the Explorer web browser. (3) Select "Tools" from top menu of the browser. And, select "Internet Options", then "Security".
(4) Enter the SNS-110 IP Address in Address : xxx.xxx.xxx.xxx (5) If you have properly logged in, you will see the following. (6) Properly enter user name and password and click "OK" icon. Then, you should see the security message.
(7) Click "Yes". You just have completed downloading Explorer plug-in program from SNS-110. Then, you will see the initial screen of Chapter 6, Application Mode. (8) If security level is set to "High",then the following window appears and the program cannot be installed. Therefore, go back and set the security level to "Medium" or lower. Warning After the Explorer download completes, please place the security level in its original position. After the First Time (1) Open Explorer web browser.
Others (1) The initial user name and password in factory defaults are as follows. ● User Name : root ● Password : w2000 (2) Log-in window appears only under the following condition. ● When "Password Enable" is set in the Web Transmitter setting of the Administration mode and you have access to the Application mode, Log-in window appears. The factory default is "Password Enable".
Chapter 6. Application Mode (Video Image Monitoring Mode) Initial Screen (1) If you have entered correct user name and password or clicked "Application" button, you will see the next initial screen of application mode. (2) You will see the quadruplex screen with 4-video image input. And, without any image input, you will see "No Video" Single Screen (1) By selecting an image from "Camera 1~4" button on left side of the screen, you will see individuals image corresponding to your selection.
Quadruplex Screen (1) Click "Quad" button on left side of the screen. You will see 4 individual screens in the quadruplex screen. (2) Click any of the 4 screens to view it in single screen. Automatic Sequential Screen (1) Click "Sequential" button on left side of the screen in Application mode. You will see 4 screen sequentially altering. The interval time between each screen can be regulated in Administration mode. (2) Screen configuration is set as in single screen condition.
Single Screen with PAN/TILT/ZOOM Controller (1) After enabling PAN/TILT/ZOOM in Administration mode, if you select an image from "Camera 1~4" button, you will see the next screen. (2) Before operating PAN/TILT/ZOOM, the PAN/TILT/ZOOM controllers must have been connected, and P/T/Z configuration must have been established in Administration mode. (3) You will see scrolling bars around the image. You may select your preferred angle and position of the image by clicking each bar.
Chapter 7 Administration Mode Initial Screen (1) You must enter "root" for the user name and its password in the Log-in window to transfer to the below Administration mode screen for both password-enable and password-disable condition. (2) If the camera does not operate normally after accessing to the Administration mode, the camera icon that is located on the screen blurs. If the camera operates normally, however, the icon shows in gray.
Camera Set-up (1) You will see the following screen by clicking "Camera" icon in Administration mode. (2) Camera Input Automatically recognizes image broadcasting system (NTSC/PAL), Color/Black &white, or No Video. If you click "Refresh" button at any time, this function will run through and set up new configuration of image broadcasting system (NTSC/PAL), Color/Black &white, or No Video. (3) Size As the size of image in the screen, you may select "Small", "Normal", or "Large".
(6) PAN/TILT/ZOOM Select "Disable", if Pan/Tilt/Zoom controller is not connected. At this time "Preset" button is inactivated. If Pan/Tilt/Zoom are properly connected, select "Enable". (7) Preset It will activate "Preset" button. At this time, you will see the next screen, and you may remotely control the position of camera. After positioning the camera as your preference with Pan/Tilt/Zoom/Focus controllers, save this position in "Current Position".
PAN/TILT/ZOOM Set-up (1) You will see the next window, if you click "P/T/Z" icon in administration mode. (2) Device To control PAN/TILT/ZOOM/FOCUS, connect the PAN/TILT/ZOOM/FOCUS camera & controller to the +, - terminals of RS-485 on the rear of your web transmitter. For further information, refer to Chapter 3. "Connecting to PAN/TILT/ZOOM/FOCUS Camera & Controller". Here are the supported PAN/TILT/ZOOM/FOCUS camera & controller.
Quad/Sequential Set-up (1) You will see the next screen by clicking Quad/Sequential icon in Administration mode. (2) Quad Size Select from either Small or Normal. (3) Sequential Size Select one from Small/Normal/Large. (4) Sequential Interval You may select the sequential interval from 3secs to 60secs. Your selected time will be the interval between 4 input images in the sequential screen. (5) System Select the image broadcasting system between NTSC and PAL, depending on where you are.
Web Transmitter Set-up (1) You will see the next configuration window by clicking "Web Transmitter" in Administration mode. (2) Date & Time Select date and time. (3) Security ① New root pswd Changes root password. New password must be more than 3 letters and less than 32, and must include Arabian numbers. Every time you log in to Administration mode, you have to enter user name and password, and only valid password is "root" password.
③ Pswd Enable Restricts the access from other users. If you check the check box of "Pswd Enable" and click "Apply" button, you should input registered username and its password in Log-in window to access to the Application mode. If you don’t check the check box of "Pswd Enable", anyone is accessible to the Application mode. Caution Anyone, who is accessible to Administration mode, may change configuration of SNS-110. If the configuration is deleted or altered, the system may be damaged or malfunction.
Caution Be careful not to install any other file except SNS-110 program (sns110_vXXX_XXXX.bin) during S/W upgrade. You might accidentally trigger the fatal system damage. Always reboot, after the system is upgraded. After upgrading, Network setting (IP Address, DNS ) is not changed but the user s input is initialized after rebooting and it has to be specified at Administration Mode.
Setting the ALARM / RELAY Out (1) Connect the alarm sensor to another device according to the ‘Chapter 3 Connecting to Instruments’. The alarm level of the alarm terminal 1~4 is the following. ● Normal condition : TTL High Level (DC 5V) ● Alarm : TTL Low Level (DC 0V) (2) If the alarm is set off the SNS-110 sends video images connected to alarm terminal 1~4, by E-mail or to the FTP server on a set time gap.
(6) Enable Each alarm terminal has to be set as for whether the "Mail" or "FTP" transfer function is going to be used. If the alarm sensor isn't installed or if the input signal can be ignored, click "No". (7) Pre-alarm If the video image transfer is set to FTP and the alarm went off, this will send the images that were sent before the alarm. The number of the video images that is sent before the alarm is equal to the 'Image No.' in item (12), and if the Image No.
Network Set-up (1) You will see the next configuration window by clicking "Network" in Administration mode. (2) IP Address Enter SNS-110 IP Address. If the IP Address has been properly set up according to Chapter 4 Setting up IP Address, the IP Address will automatically be set up and shown in the window. If the IP Address is changed in use, re-set the IP Address on this menu. . (3) HTTP Port Set the Http Port to connect to a web browser. Default setting is at 80.
(8) Gateway Set up the Gateway Address assigned by the network manager. (9) DHCP (Dynamic Host Configuration Protocol) DHCP is protocol, which automatically assigns IP address in network environment. Those network environments automatically assigned with IP Address are as follows. ● Set DHCP "Yes" at Ethernet, which uses DHCP Sever. ● Also set DHCP "Yes" at Cable Network. DHCP must be "NO" in the network environment besides the above two cases.
(11) FTP Server Specifies the FTP Server address to send still image. The server address has to be either network IP Address where SNS-110 can access or Host Name. (12) FTP Port Set the FTP Port to transfer still images to the FPT server. Default setting is at 21. (13) User Specifies the User ID to access FTP server. (14) Password Specifies the User Password to access FTP server. (15) Directory Specifies the server Directory to save the image sent through the FTP server.
File Transfer Setting (1) Click "File Server" at Administration Mode to open the following window and to specify the file transfer through the FTP server. (2) Camera 1~4 Specifies the FTP transfer for input image from Camera 1 to Camera 4. Click "No" not to use FTP transfer, click "Once" to transfer at one certain time a day, and click "Every" to send in regular time gap for certain period of time. Click "Both" to use both functions of "Once" and "Every.
(5) Between Specifies the starting and finishing time of image file transfer. It only applies to files which were set as "Every" or "Both" at (2). You can set "Time"(0~23), "Minute"(0~59), or "Second"(0~59). If starting and finishing time are identical, image files are transferred all day. (6) Day Specifies days to transfer image files. It only applies to files which were set as "Every" or "Both" at (2). You can choose the days for "Every" mode transfer.
Custom User Interface Setup (1) By clicking the "Web Browser" icon in the Administration Mode, the Custom User Interface setting window appears. Start page, page title, background color, font color and language can be set up, as the user wants. (2) Start Page The start page in the Application Mode allows a choice between one of Camera 1~4, Quad, and Sequential. (3) Page Title Here the contents and the application of the Title String, which falls under the Page Header of HTML, is set.
ABOUT/ SUPPORT/ HELP (1)ABOUT Provides you information on SNS-110. (2)SUPPORT Samsung Electronics’ English Version Homepage(http://www.samsungelectronics.com/)is linked. Search for an webTX or SNS-110, and you can download SNS-110 user manual, a last update program and troubleshooting instructions.
(3 )HELP Provides you with help messages on each function. You can see help message as shown below by clicking mode. Ex) the Help that appears when the ? ? in the configuration window of Administration is clicked on the Camera setting window.
WEB APPENDIX A SNS-110 SPECIFICATIONS 60
APPENDIX A SNS-110 SPECIFICATIONS SPECIFICATIONS Video In/Out ● Composite 4 Channel, Color & Black/White ● NTSC/PAL compatible ● BNC Type ● Loop Through Out ● 1.
Performance ● Max 30 Frame/Sec (1 User Single Mode Connection) Alarm In ● Input 4 Port ● TTL Level "Low" Active ● Sends the Video screen through E-mail/FTP in case when alarm sets off ● Pre-Alarm Relay Out ● Output 1Port ● Regular Capacity of Relay - 2A 30VDC - 0.
Regulation Approval Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
WEB APPENDIX B Factory Default 64
APPENDIX B Factory Default Factory Default sets the program back to the condition at the time of purchase. Please note that after Factory Default has been enabled, network information is also deleted, so establishing a connection is impossible. Refer to Chapter 4, Setting an IP Address, in order to set a new IP address. How to Enter the Factory Default (1) Power on the SNS-110 or push the ‘Reset’ button in front of the SNS-110 while pushing the ‘PRESET’ button.
Items Alarm / Relay Out Status Relay Out Sender Enable Receiver Subject Message Camera Image No. Time Delay Network IP Address HTTP Port DNS Domain Name Subnet Mask SMTP Server Gateway DHCP FTP Server FTP Port User Password Directory File Server Camera1 Camera2 Camera3 Camera4 Once Every Between Day Filename Web Start Page Browser Page Title Background Color Text Color Custom Logo URL Language Warning Factory Default Value Off Blank No Blank Blank Blank Camera 1,2,3,4 Mail : 1/ FTP: 10 None 0.0.0.0 80 0.
WEB APPENDIX C How to Use Console 67
APPENDIX C How to Use Console Console allows condition check-up of SNS-110 by connecting to RS-232C port, manually setting networkrelated information. Starting Console (1) Connect to RS-232C port on the PC in accordance with "Connecting to RS-232C" of "Chapter 3, Connecting other equipments” (2) Use Terminal Emulation (Hyper Terminal) from the connected PC to set the values for RS-232C through Terminal Emulation. (3) The following message will appear when you turn on the power of SNS -110.
Codec initialized, register updated. Create/Start working tasks... (f_CompVideo()) JCPY task start (id=1638400) AlarmCheck task start (id=1703936) Mailing task start (id=1769472) PTZ control task start (id=1835008) Create FTPClientTask.. Enter the loop. Create PreAlarmTask. All Task started. Wait until jpeg task ready... Launch Webcontrol server as new thread. WebServer task created. now starting.. >Relay Status : 0 wt_cookie initialized.
Command (1) help: Indicates Command items SNS-110> help telnet ping help SNS-110> status tftpdn reset freset jpgtest (2) ping: Indicates the connection status to a given IP Address SNS-110> ping 168.219.13.115 ping (168.219.13.115): 56 data bytes 168.219.13.115 is alive SNS-110> (3) status: Indicates the current condition and information of SNS-110 SNS-110> status size of data = 2144 SNS-110 System Parameter List Version sns110.1.1 build 01.10.16.13.
--User information number of user : 2 user list 0 1 --Camera setting Cam1 : size 1, CR 0, title off, <> Cam2 : size 1, CR 0, title off, <> Cam3 : size 1, CR 0, title off, <> Cam4 : size 1, CR 0, title off, <> Quad size 1, Quad mode 0, Seq size 1, Seq interval 1 Cam ptz control 0 0 0 0 User password enabled (1) --Alarm parameter alarm1 no, rcv addr , sender addr , camera 1, 0/10 images, interval 0 subject <>, message <> alarm2 no, rcv addr , sender addr , camera 2, 0/10 imag
(4) tftpdn : Using the ftp Server, software can be downloaded as the following. First the tftpdn Server has to be running on the PC with the new software. The tftp Server isn't offered separately. Users must use their own tftp server programs. SNS-110> tftpdn **************************************************************** * Main Image Download & Flash Update by TFTP * **************************************************************** >TFTP Server(Default:0.0.0.0) : 168.219.13.101 >TFTP Server : 168.219.13.
(6) freset : the SNS-110 settings are initiated for factory shipment SNS-110> freset Setting HTTP port to 80 and FTP port to 21. >Application cookie field initialized. Cookie App field initialized. ftp server addr invalid. For complete erase, use PRESET button. End of WT_FTP_INIT SNS-110> Manual Configuration Mode (1) Once you turn the power on and SNS-110 functions normally, the following message will appear, and if you press any key, you will be able to set the values manually.
>Ethernet(MAC) address in Cookie : [00-00-f0-ff-a1-ba] >Forced to use DHCP for IP address setting(DHCP Flag=0x1) >Stored IP address <00000000> is not valid! >RARP(Fixed IP) Mode -> Try to find IP : Retry No.[1] >Ethernet(MAC) address in RARP mode : [00-00-f0-ff-a1-ba] ..... >DHCP(Dynamic IP) Mode -> Try to find IP : Retry No.[1] ..... >RARP(Fixed IP) Mode -> Try to find IP : Retry No.[2] >Ethernet(MAC) address in RARP mode : [00-00-f0-ff-a1-ba] ..... >DHCP(Dynamic IP) Mode -> Try to find IP : Retry No.[2] .
tftp server address: 0.0.0.0 tftp boot file:[rom.bin] DHCP Enabled:[1] IP auto-reg server:[NULL] IP auto-reg cgi:[/cgi-bin/webtx.cgi?regist=%e&host=%i] IP auto-reg enable:[1] IP notify-mail address:[webtx@samsung.co.kr] IP notify-mail enable:[1] -------------------------------------------[WEB Transmitter(SNS-110) Version 1.
(5) If there is information you would like to change or update, you can do so at this time. Select items? [ ] i LAN IP address? [0.0.0.0] 168.219.13.113 168.219.13.113 Turning off DHCP mode.... Warning To use the Static IP Address, put "0" for DHCP flag and to use the Dynamic IP Address, put "1." The default is "1" but when you change IP Address, DHCP flag is automatically changed to "0." Confirm for more accurate setup. (6) If you enter "q" when "Select items?" appears, you will go back to menu of (2).
WEB APPENDIX D Dynamic IP Information Transfer 77
Appendix D Dynamic IP Information Transfer In such an environment where you have to be assigned with Dynamic IP as Cable Modem, you need separate method since users cannot know IP information. SNS-110 uses two methods to show the Dynamic IP information to users. One is to send IP information to the administrator’s email, and the other is to send the Dynamic IP information to the Administration server. ● For this function to properly work, SMTP, DNS, or Gateway have to be all properly set.
Enter "5" and go to IP notify-mail address to type E-mail address you want. Select items? [ ] 5 IP notify-mail address? [webtx@email.com] user@samsung.co.kr Enter "4" and go to IP notify-mail enable/disable and enable it. Select items? [ ] 4 IP notify-mail enable? [Y] Select Quit menu to exit Boot Command Mode. When all the network settings are properly installed and DHCP function is enabled, Dynamic IP information is sent to the email, which was set while SNS-110 was booting.
Registering IP information with Administration server Install HTTP server, which can process the Properties transmitted by SNS-110, or receive separate service from the Service Provider to register IP information with Administration server. Dynamically assigned IP information can only be set at SNS-110, whether which name or server will be used. If you cannot access the browser, use the console to set up.
Type "1" and go to IP auto-regist server address" to type registered Web Server address. The example below is the IP Address such as 168.219.44,137 or registered host name such as www.samsung.co.kr. [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------[i]. Ip address modify . . . . [q]. Quit menu -------------------------------------------Select items? [ ] 1 IP auto-regist server? 168.219.44.
%g : Ethernet address (standard) Example: 00-00-f0-ff-a1-42 %i : IP Address (dotted decimal) Example: 168-219-44-137 %u : IP Address (32bit unsigned integer, hex form) Example: a8db2c89 %% : Means % Select Quit Menu to exit Boot Command Mode. [ WEB Transmitter ( SNS-110 ) Version 1.1 ] Boot parameters modification menu -------------------------------------------[i]. Ip address modify . . . . [q].
Setting with the Web Browser When you have SNS-110 address and can access through the Web Browser, you can change the setting as above at the Administrator Mode. When you run the Network Setting window as explained in the Chapter 7 and click "Advanced" for DHCP, the Dynamic IP setting window appears as below. You can change or add the values set at the Console. CGI Program for the Administration Server Refer to http://www.samsungelectronics.
WEB APPENDIX E FAQ 84
APPENDIX E FAQ As you continue to use SNS-110, there could be some cases, which we have not yet discussed in this manual. In such a case, it might actually be when SNS-110 has an error. But in most cases, an easy do-itright can fix the difficulties. Please react to the symptoms by following the instructions below. When you get no Message after connected SNS-110 and PC with RS-232C Cable and executed Terminal Emulation Program (e.g. hyper terminal).
(2) If LED of Network for SNS-110 is working correctly, the values for Network within SNS-110 might have been incorrectly entered. In such a case, refer to Supplement B Factory Default to turn the settings to the factory mode. Then, retry setting the IP address again, as shown in Chapter 4. The PC to setup the IP Address at SNS-110 must use the IP Address that has the same network as the IP Address to setup at SNS-110. For example, the IP Address you want to be authorized with SNS-110 is 168.219.15.
When the post-version software still operates, even after you have installed the updated version. (1) When you upgrade to the latest version of the software, the "Uploading is successful! New code will be loaded after reset" message appears. When this message appears, reset or restart SNS-110 and the new software will reboot the system. (2)To check the version, press "about" in "Administrator Mode" in SNS-110.
If the Video image has problems when connected to SNS-110 using a Netscape (1) This can happen if Netscape 6.0 or above is used. (2) Use Netscape 5.X or below. (3) The defects related to Netscape 6.0 are being fixed. You cannot use FTP for transfer when setting up FTP transfer (1) Check [Start] – [Settings] to see if current time is set for SNS-110. If the current time is not properly set, FTP transfer does not work.
ELECTRONICS AB68-00278A