31
mounting pattern.
Insert mounting bolts into slotted holes in flange.
Push fit flange through hole to floor and secure flange to floor using flat head screws through
the countersunk holes in flange (see FIGURE B).
FIGURE B
If desired spread bead of silicone sealant around outer edge of floor-flange (seeFIGURE C).
FIGURE C
Place and align rubber toilet seal over mounting bolts on floor flange.
Set and mount low water toilet in place by using bolts protruding from rubber seal and floor
flange (see FIGURE D).
Install washers and hex nuts to mounting bolts.
Tighten nuts down equally using 7/16”/11.125cm wrench (or adjustment).
FIGURE D
Turn off water supply.
Your low water toilet comes with a 12.0”/30.48cm water supply line (3/8” to 0.5” or 9.525mm to
12.7mm).
Connect securely 3/8”/9.525mm end of water supply line to proper bathroom plumbing
connection (recommend having shut off valve installed on bathroom water supply plumbing
line).
Connect 0.5”/12.7mm end of water supply line to low water toilet (located at back of foot
pedal) to water valve 0.5”/12.7mm MPT inlet using 0.5” fittings on water supply line (see
FIGURE E).