Place 4”/110mm Flex Vent pipe section over vent opening on the Top Panel of Envirolet®/SG Composting Unit (tank) using
the supplied 4”/110mm stainless steel Gear Clamp.
Tighten Gear Clamp over Flex Vent to secure to plastic opening for proper seal.
Based on your individual installation requirements, you may wish to increase or decrease the length of the 100mm/4” Flex
Vent pipe (4’/1.2m is standard).
IMPORTANT
Seal vent connection on Top Panel securely with 4”/110mm Gear Clamp and Silicone Sealant provided to prevent odours.
IMPORTANT
Install minimum of 12”/30cm of 4”/110mm Flexible Vent Pipe that connects composting unit to 4”/110mm rigid pipe section(s). This will
prevent rigid pipe breakage due to possible ground shifting caused by freezing temperatures or other movement.
3. Install Rigid Vent Pipe (not supplied)
Rigid Vent
Not included, due to transportation costs, is 10’/3m to 20’/6m (for a typical installation) of rigid ABS or PVC Pipe that is required to
complete vent installation. This rigid pipe travels up along the wall of your structure above the roof line (minimum 2’/0.6m) and is fitted
with the included Wind Turbine Ventilator. The rigid pipe connects to the 4”/110mm Flex Vent Pipe via an attached 4”/110mm
coupling provided. This low-cost rigid pipe can be easily acquired from your local dealer or at your local hardware, plumbing or home
center.
o Determine length of 4”/110mm rigid vent pipe required for your installation. To properly determine length of
rigid vent pipe required be sure to allow a minimum of 2’/0.6m 3’/0.9m rigid vent pipe to extend above
the structure roof line to ensure proper vent draft and maximum performance of the 4”/110mm Wind
Turbine Ventilator.
Position rigid pipe as close as possible to the vent exit on the Envirolet®/SG Composting Unit. Again, it is very
important to avoid any 90° bends in your vent installation.
Attach rigid pipe securely to wall from just above Envirolet®/SG Composting Unit entire way up wall to above roof line. Each
installation will vary significantly, depending on location requirements. For added performance insulate all rigid vent pipe.
4. Connect Flexible Vent and Rigid Pipe
Connect the flexible vent with supplied (Scandinavia only) 110mm Coupling to rigid pipe.
5. Attach Wind Turbine Ventilator
Attach the 4”/110mm Wind Turbine Ventilator to the top of the rigid vent pipe using straight coupling (not supplied).
Secure the Wind Turbine Ventilator with silicone sealant and at least 3-4 tapping screws (not supplied).
IMPORTANT
Extend the 4”/110mm rigid vent pipe higher than 3’/0.9m minimum for any installation surrounded by high trees, hills, other structures
and/or with a high roof peak and/or located in a valley.
6. Seal All Vent Connections
Seal all vent connections with silicone sealant. This is an important step because it will help prevent any odour
leakage. Even a small hole can lead to odour escape, so please double check.
7. Install Drain
Connect one side of “T” portion of quick connect breather “T” to ½”/13mm drain (5’/152cm included standard) line that exits
Compost Unit (bottom right-hand side when facing tank).