Use and Care Guide

Table Of Contents
Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
41
Important
Make sure open part of “T” (middle) is facing up to prevent air-lock.
Connect other side of “T” to length of 13mm/1/2” drain line.
Place end of drain line to an acceptable drain site (leach field, holding tank, liquid container, etc.). See Draining
Information section for more details. Make sure there is a gravity drop the entire path from composting tank drain exit to
drain site.
Insulate drain line if there is a chance of freezing.
IMPORTANT
Please be sure to connect excess fluid drain to an acceptable drain site, according to local regulations.
8. Connect Three Components of System
Once all three components (vacuum toilet, Vacuum Generator, composting unit) are in place, you are ready to connect them! Please
continue to Connection & Set-Up section for information connecting the components.
IMPORTANT
Do not attach Envirolet®/SG Composting Unit to floor/ground until completing system set-up.
Envirolet®/SG FlushSmart VF: Three Main Components Connection & Set-Up
Installation instructions for connection the three main components of the Envirolet®/SG FlushSmart VF System.
PLEASE READ THIS SECTION CAREFULLY.
Connection & Set-Up
IMPORTANT
Follow all safety guidelines before connecting and starting your Envirolet®/SG FlushSmart VF system.
Installation is almost complete! Now you have to connect the three system components to create the complete Envirolet®/SG
FlushSmart VF System.
IMPORTANT
Please follow these steps carefully before attaching/fastening any component to the floor.
Connect Vacuum Toilet to Vacuum Generator
o Connect one end of 1.5/38mm drain hose to vacuum toilet discharge, depending on model: