Draining & Typical Drain Pit Design
Draining information and typical drain pit design.
PLEASE CHECK LOCAL REGULATIONS REGARDING DRAINING.
Some systems are fitted with an excess liquid drain kit. This drain must gravity connect to a leaching pit or acceptable drain site for
proper system performance.
Systems with drain kit included standard:
All Non-Electric models.
All 12VDC models.
All water flush (Low Water Remote and FlushSmart VF) models.
Important - Add Drain to AC Waterless System, If Required
As a rule of thumb, AC Electric Waterless models (e.g., Envirolet®/SG MS10 and Envirolet WRS AC) do not require a drain. However,
it is recommended to install an excess liquid drain on any model (including AC Electric Waterless models that normally do not require
a drain), if any of the following applies to the installation:
System is installed in any continuous or heavy use application (i.e., residential use, commercial use, public use).
System is going to be used without power or (due to power outages or for power saving).
System is not going to be used in Normal Mode/Position 2 (for power saving) all of the time when in use.
Envirolet®/SG Waterless Self-Contained and Waterless Remote Systems
Non-Electric & 12VDC battery powered Waterless Self-Contained Systems and Waterless Remote Systems are equipped with a Drain
Kit and must be connected to an acceptable drain site. This is optional on AC Electric Waterless models.
Gravity connect drain line exiting Envirolet®/SG System in the following method:
Connect to an acceptable* black water drain pit/site (see instructions for a typical design below)
Or, connect to a holding tank (will require periodic emptying to proper disposal site).
Or, connect to a 5 gallon plastic container (will require periodic emptying to proper disposal site).
A drain pit is ideal where possible.
In order to allow for proper flow the drain line must be gravity connected its entire path from toilet system to drain site.
Ensure that Quick Connect “T” is used with the breather tube pointing upwards to prevent air lockor drain blockage.
Envirolet®/SG Low Water Remote and FlushSmart VF Flush Systems
All Low Water Remote and FlushSmart VF Systems are equipped with a Drain Kit.
Gravity connect drain line exiting Envirolet®/SG System in the following method:
Connect to an acceptable* black water drain pit/site (see instructions for a typical design below)
Or, connect to a holding tank (will require periodic emptying to proper disposal site).