Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
53
Rated CapacityMaximum Use
Each type or model of Envirolet®/SG Composting Toilet Systems has a rated capacity. Do not use above these rated capacities
except for brief periods of time.
IMPORTANT
Any system that will be used above the rated capacity, even for short periods of time, should have an excess liquid drain installed.
Look for your system/model below and use within capacity.
Rated Capacity Chart
System
Model/Series
Power
Users/Day
(FULL-TIME)
Users/Day
(PART-TIME)
Drain Required?
Envirolet Waterless Self-Contained
Basic Plus
Non-Electric
2
4
Yes
Envirolet Waterless Self-Contained
DC12
12VDC
4
6
Yes
Envirolet Waterless Self-Contained
MS10
AC Electric
6
8
No¹
Envirolet Waterless Remote
NE
Non-Electric
4
6
Yes
Envirolet Waterless Remote
DC
12VDC
6
8
Yes
Envirolet Waterless Remote
AC
AC Electric
8
10
No¹
Envirolet Low Water Remote
NE
Non-Electric
4
6
Yes
Envirolet Low Water Remote
DC
12VDC
6
8
Yes
Envirolet Low Water Remote
AC
AC Electric
8
10
Yes
Envirolet FlushSmart VF AC
300 700 800
AC Electric
8
10
Yes
Envirolet FlushSmart VF DC
320 720 820
12VDC
6
8
Yes
Envirolet FlushSmart VF AC
350 750 850
AC Electric
16 (8/tank)
20 (10/tank)
Yes²
Envirolet FlushSmart VF DC
370 770 870
12VDC
12 (6/tank)
16 (8/tank)
Yes
Footnotes
1 Drain is not required under normal use. Please refer to important message below for more info.
IMPORTANT - ADD DRAIN TO AC WATERLESS SYSTEM, IF REQUIRED
As a rule of thumb, AC Electric Waterless models (e.g., Envirolet®/SG MS10 and Envirolet WRS AC) do not require a drain. However,
it is recommended to install an excess liquid drain on any model (including AC Electric Waterless models that normally do not require
a drain), if any of the following applies to the installation:
ü System is installed in any continuous or heavy use application (i.e., residential use, commercial use, public use).
ü System is going to be used without power or (due to power outages or for power saving).
ü System is not going to be used in Normal Mode/Position 2 (for power saving) all of the time when in use.
2 No drain operation is possible with maximum of 4 people/day. Ask for details.
3 Available in Norway only.
Notes
Users/day refers to the number of users per day at three uses each per day.
Full-time use refers to permanent type use (residential or business).
Part-time use refers to cottage-type use (seasonal).
Rated capacities only apply if system is operated as directed. For example, with AC Electric models the fans and heater
should be on at all times when the system is in use.