Installation Issues &
Errors
Installation “errors” can lead to any
of the above troubleshooting issues.
It is essential that your system be
installed correctly for it to perform
properly. In this section we will list
some possible or common
installation errors (or shortcuts) that
can lead to later difficulties.
Important:
Please do not assume that you
can “shortcut” proper installation
or that a different way is equal to
the way outlined in our
instructions.
Venting
Do not use 90° bends in vent. This is mentioned numerous times throughout this
manual.
o This will cause significant evaporation issues.
Do not use your own vent pipe instead of the vent pipe supplied with system.
o This pipe may be smaller than the normal vent pipe used with your system
and this can cause evaporation issues.
o This pipe may be metal, which can corrode.
o Fittings may not attach securely.
Do not place a screen or mesh cover over the vent opening.
o This will cause significant evaporation issues.
o Do not use alternative vent “caps” other than the supplied Wind Turbine
Ventilator.
Insulate all venting, in Waterless Self-Contained Systems, which are outside, in an
attic or cold air space.
Draining
Do not ignore the drain! It must be connected in any system that it is
included with. The drain must be gravity fed the entire path from toilet to
drain site.