Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
37
SINGLE TANK SYSTEM
DOUBLE TANK SYSTEM
Below are some things to consider before beginning the installation process.
Position the System
Position the vacuum toilet, vacuum generator and Envirolet®/SG composting unit in an area that is free of obstructions (pipes, electric
boxes, wires, etc.). Try to keep composting unit in area with an ambient temperature above 12°C (55°F) for optimum
composting. Refer to the Winter Use section if you plan to use the system in freezing or near-freezing temperatures.
Protect from the Elements
For safety and performance, the Envirolet®/SG composting unit, vacuum generator and 12V power supply unit (and any other electric
components) must sit horizontally on a flat dry surface and must be installed in a vented covered structure (work shop, shed, box, etc.)
to protect from the elements (water, rain, snow, etc.) and to protect from electrical damage or hazard. Refer to the Safety
Guidelines section for more info on safe installation and operation.
Envirolet®/SG FlushSmart VF: Maximum Distances Component-To-Component
Information on how far apart Envirolet®/SG FlushSmart VF components can be from one another.
PLEASE READ THIS SECTION CAREFULLY.
One of the great features of the Envirolet®/SG FlushSmart VF model is that it can flush up, down or sideways! Be sure to follow these
maximum distances when installing your system.
MAXIMUM DISTANCES
In order to ensure proper system performance the following component-to-component maximum distances must be followed.
Note, the maximum overall height (vertical “flush up”) is 12’/3.6m and the maximum overall
distance (horizontal) is 70’/21m.
The head from vacuum toilet to vacuum generator can be as much as 6’/1.8m maximum.
Headrefers to the height from bottom of vacuum toilet to vacuum generator.
The vacuum toilet and vacuum generator can be up to 50/15m apart maximum.
Be sure to maintain maximum head distance (6’/1.8m).
The head from vacuum generator to Composting Unit can be as much as 6’/1.8m maximum.
Headrefers to the height from vacuum generator drain outlet to drain inlet on Composting Unit.
The vacuum generator and Composting Unit can be up to 20/6m apart maximum.
Be sure to maintain maximum head distance (6’/1.8m).