and not through the toilet for best results.
Use Aerator Bar
Pull the Aerator Bar in and out a few times every week.
You can use the Aerator Bar (details below) more often, but please try and use at least
every week. Learn more in the Aerator & Rake Bar Operation section.
TIP: WET OR DRY
If compost appears too wet (or soupy”) then add and mix more dry additives until compost is dry.
If compost appears too dry (or clay-like) then spray small amounts of water evenly over compost to moisten.
Refer to Troubleshooting section for more tips.
6. Mid-Season
Mid-Season Preventative Care
It is recommended to try and do a few preventative maintenance steps mid-season to
prevent any possible issues. These steps should not take more than a few minutes
each.
Check all air and liquid seals
Visually inspect that all openings in system are completely sealed for liquid and
air.
Make sure bottom panel is properly attached and that all areas that silicone-
sealed have a proper seal.
7. Pre-Winter
Prepare for Winter Use
If you plan your system in the winter then proper winterizing precautions must be
followed well before the start of the winter season. Refer to system-specific Winter
Use section for complete details.
8. End of Season
End of Season Preventative
Care
Similar to the mid-season point, it is recommended to try and do a few preventative
maintenance steps at the end of the season (leaving the system for an extended period)
to prevent any possible issues. These steps should not take more than a few minutes
each.
Check all air and liquid seals
Visually inspect that all openings in system are completely sealed for liquid and
air.
Make sure bottom panel is properly attached and that all areas that silicone-
sealed have a proper seal.
Check Electric Components
1. Listen to fans. It is not always possible to know if both are working (i.e., you may
hear one fan and not know if other is functioning) but this is a good initial test.
2. Test if both fans (DC and AC models) are working with paper or bag test:
a. Place thin piece of paper or plastic bag over toilet seat area (Waterless
models) or Service Panel louvered vent (Low Water Remote and
FlushSmart VF models).
b. With proper vent fan operation the paper or bag will be drawn in.
3. Turn heater on (AC models). Wait about 5-10 minutes and feel middle of top
panel. If heater is functioning it should be slightly warm to the touch.
4. The electrical box in systems older than 5 years should be inspected annually.
Electrical Problems?