User manual

TECHNICAL DATA
Oecoplan 1590 GTA++ Oecoplan 3270 GTA++
Volume (net) Litre 159 327
Height mm 876 876
Width mm 946 1611
Depth mm 665 665
Rising Time hours 48 58
Energy Consumption kWh/24h 0,430 0,616
Freezing Capacity kg/24h 20 31,5
Climatic Class SN-N-ST-T SN-N-ST-T
Further technical information are situated in
the rating plate on the external right side of
the appliance.
INSTALLATION
Positioning
Warning! If you are discarding an old
appliance that has a lock or catch on
the lid, you must ensure that it is made
unusable to prevent young children
being trapped inside.
Important! The appliance shall have the
plug accessible after installation.
This appliance can be installed in a dry, well
ventilated indoor (garage or cellar), but for
optimum performance install this appliance
at a location where the ambient tempera-
ture corresponds to the climate class indi-
cated on the rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Electrical connection
Your appliance must be connected to a sin-
gle-phase supply of 230 V. Check that the
electricity meter is suitable for the power
consumed by your appliance, allowing for
the other connected appliances. Rating of
the in-line fuses (one per phase): 10 A at
230 V.
Important! Installation must be done in
conformance with the applicable codes, the
requirements of the standard NF.C.15100
and the requirements of the electrical
energy supplier.
Use a power supply socket that has an
earth connection and this must be connec-
ted in conformance with the standard
15100 and the requirements of the supplier
of electrical energy. this power supply sock-
et must be accessible. If the mains supply
cable is damaged, it must be replaced by a
certified supply cable. This must be done
only by a skilled person, the seller or the
manufacturer. The appliance must not be
connected via an extension cable, a multi-
ple socket or a multiple connector (risk of
fire). Make sure the earthing connection
complies with the regulations in force.
We will accept no responsibility in the event
of accidents or incidents caused by non-ex-
istent or defective electrical earthing con-
nections.
Ventilation requirements
1. Put the freezer in horizontal position on
a firm surface. The cabinet must be on
all four feet.
2. Make sure that the clearance between
the appliance and rear wall is 5 cm.
3. Make sure that the clearance between
the appliance and the sides is 5 cm.
43