Technical data

23
4000123924-2
11 Horizontal Telescopic Top Flue Installation
11886a
The Horizontal Telescopic Top Flue,
Kit No. A2004500
Suitable for installations that require a flue length "L" from 430
minimum to 660 maximum. If longer flueing is required
extensions and bends are available, see note below.
If the flue length, see diagram 11.2. is less than 430 'L' Do Not
cut this flue but use the horizontal top flue 86285.
Note: Additional 1 metre extensions, 90° and 45° bends are
available. The maximum extended flue is 3.5m. The use of flue
bends requires the max extended flue lengths to be reduced by
1m. for 90° and 0.5m. for 45°.
11.1 Horizontal Telescopic Top Flue
Kit of parts, refer to diagram 11.1.
11.2 Horizontal telescopic flue system
Rear and side flue lengths and dimensions, see diagram 11.2.
10322a
The flue kit A2004500 is 660 mm long and comprises:
-Telescopic flue assembly ..................................... A
- Fixing collar seal .....................................................B
- Fixing collar............................................................. C
- Elbow....................................................................... D
- External rubber sealing collar ...............................E
- *Gasket ....................................................................F
- *Screws 6 off...........................................................G
- *'O' rings .................................................................. H
- *Screws 4 off............................................................ J
* supplied in plastic bag
Diagram 11.1
Telescopic Top flue kit
A
B
C
E
D
F
*
H
*
H
*
Diagram 11.2
G
*
J
*
Drill, Screw and
Tape (not supplied)
70mm
65m
450 mm
225mm
20mm
Min. Clearance
70mm
232 mm
65mm
SIDE FLUE
EAR FLUE
L
L
Note :
Top of boiler
casing not
front panel
Note :
Top of boiler
casing not
front panel
* refer to diagram 6.1