Tus neeg siv phau ntawv

Climate Class
Max. Environment Temperature
Max. Relative Humidity
3
25 °C
60%
4
30°C
55%
5
40 °c
40%
The minimum operating temperature is 10 °C
Technical Safety:
This equipment has a small amount of refrigerant (R600a or R290,
depending on the model) which, while not non-polluting, is
flammable. Care should be taken to ensure that the refrigerant tube
is not damaged during transportation or assembly. The refrigerant
may cause damage to the eyes or ignite when released.
In case of damage:
Keep the equipment away from naked flames or ignition sources;
Air out the cabinet well for a few minutes;
Disconnect the plug from the mains;
Contact the technical service.
The compartment where the equipment is installed should be as big
as necessary for the refrigerant in the appliance. In very small spaces
and in the event of a leak, a flammable gas/air mixture may form.
The compartment should be at least 1m
3
for every 8 gr of refrigerant.
The amount of refrigerant in the appliance is indicated on the rating
plate inside the same appliance
Replacement of the electrical cable and other repairs may only be
carried out by qualified service personnel in order to prevent
dangerous situations. Improper installation and repairs can result in a
number of hazards to the user.