Tus neeg siv phau ntawv

TROUBLESHOOTING GUIDE
Problem
Solution
The Appliance is not
working
Check for power outage
Check if there is current in the socket
The equipment works, but it
is not very cold
Check for the build-up of dust on the condenser
Check controller setting
Check if fans (when applicable) are working or are stuck
Check ice build-up on the evaporator
Check that the door is properly closed
Water appears on the
bottom of the equipment
Check that the drain hole is not blocked or that the tube is not in
the direction of the recipient in the compressor compartment
Check equipment levelling
High temperature alarm (HI)
Check ice build-up on the evaporator
Check that the fans work (when applicable)
Make sure the door was not left open for too long
Low temperature alarm (LO)
Check thermostat temperature
Turn the equipment off for 5 minutes and then switch on again
Lighting does not work
Turn the digital key on/off with the light switch function
Excessive build-up of ice
(negative cold storage
models)
Check the temperature and humidity of the environment in
which the equipment is inserted, according to the climatic class
shown on the nameplate.
Check door seal
Damaged power cord
If the power cord is damaged, it must be replaced by the
manufacturer, authorized service agent, or qualified personnel
in order to avoid danger