User`s manual

Optional Accessories
Wiring Instructions for WC-ASOKIT
1. Turn off unit and unplug from power source.
2. Remove blower duct.
3. Remove the two #2 square headed screws from the top of
the unit and remove the top.
4. Unplug the pump and motor at the top of the electrical corner.
5. Remove the two #2 square headed screws from the electrical
corner and remove the corner.
6. Remove the paper from the double-faced tape on the back of the relay. Stick the relay to the aluminum frame on the inside of the
electrical corner approximately 5" from the top of the frame; ensuring the terminals are pointing downward. See diagram.
7. Remove the grate and pads from the side of the unit to the left of the electrical corner.
8. Utilizing the electric screwdriver and the 5/16" hex head bit, attach the supplied pump brace to the blower with the two self-tapping
screws from the hardware bag. This should be done in the same manner as the pump is attached, but place it on the left side of the
blower and ensure the bottom of the brace is 2" from the bottom of the reservoir.
9. The float switch is already attached to the supplied pump brace with an 8" cable tie. Ensure there is 3" of cord from the right side of
the pump brace to the float and that the float does not hit the frame (See diagram). Note: Do not remove cable tie from pump
brace.
10. Run the cord for the float switch up through the bottom of the aluminum frame on the electrical corner.
11. Remove the cord connector. It is located at the bottom of the electrical corner.
12. Drill a 31/64" hole in the electrical corner approximately 7/8" below the switch, and insert the indicator light into the hole. See
diagram.
13. Place the female disconnect on the indicator light labeled L1 on Post 5 of the relay.
14. Remove the blue spade connector and wire from the L position on the switch with a Phillips head screwdriver, and insert the spade
connector from the jumper labeled A into the L position on the switch.
15. Cut the black wire from the power cord just below the blue connector and then strip ½" of plastic from the black wire.
16. Twist the bare end of this wire together with the L2 wire from the indicator light, the A jumper from the switch, and the jumper labeled
B that comes from Post A on the relay. Connect all four of these wires together with a red wire nut from the hardware bag.
17. Unscrew the yellow wire nut that is on the three white wires, and separate the white wire that goes to the pump pigtail and attach the
female disconnect from the hardware bag to this wire. Place this disconnect on Post 2 on the relay.
18. Twist the white wire from the power cord, the white wire from the motor cord, the wire labeled F2 on the float switch, and the jumper
labeled C from Post 7 on the relay all together and connect all four of them with a red wire nut from the hardware bag.
19. Connect the female disconnect that is attached to the wire labeled F1 on the float switch to Post B on the relay.
20. Re-install the cord connector into the electrical corner.
21. Place the electrical corner back into the bottom, but do not re-attach with the screws.
22. Plug the pump and motor in and test the operation of the float switch.
23. Place the two #2 square headed screws into the electrical corner.
24. Place the top back on the unit and re-insert the two #2 square headed screws.
25. Place the blower duct back on the unit and secure it down with the top knob.
Troubleshooting the WC-ASOKIT
WC-ASOKIT not shutting off
Ensure wiring is done properly.
Ensure the float switch is at an acceptable depth.
WC-ASOKIT shutting off too soon
Ensure the float switch is at an acceptable depth.
Ensure water is at least three to five inches deep.
The Automatic Shutoff Option (WC-ASOKIT) is available at the
time of your WayCool
®
purchase or as a retrofit kit on a
previously purchased WayCool
®
.
The WC-ASOKIT shuts off the pump when the water level gets
low and prevents the pump from damage. The warranty on the
pump is void if it is run dry.
Automatic Shutoff Option
17