Operation Manual

www.schaerer.com Programming
BASCP_EN
V03 | 08.2012
42
Preventive maintenance (bevera-
ges)
Preventive maintenance (months)
Preventive maintenance (litres)
Descaling (months)
The parameter settings listed here are made
by the service technician and are visible in
the "Caretake profile" as information.
--
Filter change, number (litres) When performing a filter change:
Enter the filter service life (service techni-
cian).
0 - 10000 The range can be read
from the filter packaging.
Filter change, number (months) The parameter settings listed here are made
by the service technician and are visible in
the "Caretake profile" as information.
--
Water hardness (dkH) The water hardness is entered by a service
technician during the commissioning pro-
cedure. Because water quality changes con-
tinuously, the water hardness should be
measured whenever the filter is changed.
Enter the result (service technician).
0 - 50 A carbonate hardness tes-
ter with 2 test strips is
included in the scope of
delivery of the machine.
Additional test strips are
available through your
Service partner.
"Water supply" menu item
Display text Description Setting range Notes
Water supply source Aquachange switching
Option 1: Switch from drinking water tank
to fixed mains water supply
Open service door and remove drinking
water tank.
Screw in Aquachange screw with a
screwdriver (size 3).
Put the drinking water tank back in place
and shut the service door.
Set the water supply source to "Fixed
main water supply".
Option 2: Switch from fixed mains water
supply to drinking water tank
Open service door and remove drinking
water tank.
Unscrew in Aquachange screw with a
screwdriver (size 3).
Put the drinking water tank back in place
and shut the service door.
Set the water supply source to "Int. drink-
ing water tank".
Fixed mains
water supply /
Int. drinking wa-
ter tank
Aquachange screw
"Maintenance" menu item
Display text Description Setting range Notes