Freedom XI Owners Guide.book Page i Friday, September 18, 2015 2:57 PM TM TM Product image shown may vary from actual product. See features for comparisons.
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page i Friday, September 18, 2015 2:57 PM Copyright © 2015 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Freedom XI Owners Guide.book Page ii Friday, September 18, 2015 2:57 PM About This Guide Purpose The purpose of this Owner’s Guide is to provide explanations and procedures for operating, maintaining, and troubleshooting a Freedom Xi Sine Wave Inverter for Recreational, Fleet Vehicle, or Marine installations. For complete information to help in installing a Freedom Xi Sine Wave Inverter see the Freedom Xi Sine Wave Inverter Installation Guide (Doc. Part Number: 975-0753-01-01).
Freedom XI Owners Guide.book Page iii Friday, September 18, 2015 2:57 PM Important Safety Instructions IMPORTANT: READ AND SAVE THIS OWNER ’S GUIDE FOR FUTURE REFERENCE. This guide contains important safety instructions for the Freedom Xi Sine Wave Inverter that must be followed during operation and troubleshooting. Read and keep this Owner’s Guide for future reference.
Freedom XI Owners Guide.book Page iv Friday, September 18, 2015 2:57 PM Safety Information 1. 2. 3. 4. 5. 6. 7. 8. iv Before using the Inverter, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual. Use of accessories not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or injury to persons. The inverter is designed to be connected to your AC and DC electrical systems.
Freedom XI Owners Guide.book Page v Friday, September 18, 2015 2:57 PM DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. • This equipment must only be installed and serviced by qualified electrical personnel. • Turn off all power supplying this equipment before working on or inside equipment. • Always use a properly rated voltage sensing device to confirm power is off.
Freedom XI Owners Guide.book Page vi Friday, September 18, 2015 2:57 PM CAUTION ELECTRICAL SHOCK AND FIRE HAZARD • • • • • • • • Do not open. No serviceable parts inside. Provided with integral protection against overloads. Bonding between conduit connections is not automatic and must be provided as part of the installation. Read manual before installing or using. Do not cover or obstruct ventilation openings. Do not mount in zero-clearance compartment – overheating may result.
Freedom XI Owners Guide.book Page vii Friday, September 18, 2015 2:57 PM Precautions When Working With Batteries 5. Important: Battery work and maintenance must be done by qualified personnel knowledgeable about batteries to ensure compliance with battery handling and maintenance safety precautions. 6. WARNING 7. BURN FROM HIGH SHORT-CIRCUIT CURRENT, FIRE AND EXPLOSION FROM VENTED GASES HAZARDS • Always wear proper, non-absorbent gloves, complete eye protection, and clothing protection.
Freedom XI Owners Guide.book Page viii Friday, September 18, 2015 2:57 PM Precautions When Placing the Inverter WARNING FIRE HAZARD Do not install the inverter or any part of its supplied wiring in engine compartments. Failure to follow these instructions can result in death or serious injury. Regulatory The Freedom Xi Sine Wave Inverter is certified to appropriate US and Canadian standards. For more information see “Regulatory Approvals” on page 32.
Freedom XI Owners Guide.book Page ix Friday, September 18, 2015 2:57 PM FCC Information to the User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page i Friday, September 18, 2015 2:57 PM Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . .
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page 1 Friday, September 18, 2015 2:57 PM Introduction The Freedom Xi Sine Wave Inverter (Freedom Xi) is designed with integrated inverting functions and power management features suitable for marine, recreational, and commercial vehicle installations. Freedom Xi unit Display panel is attached to the unit. Freedom Xi 1000 120VAC shown. Please read this chapter to familiarize yourself with the main performance and protection features of the Freedom Xi.
Freedom XI Owners Guide.book Page 2 Friday, September 18, 2015 2:57 PM Introduction Key Features Power for Most Appliances The Freedom Xi inverter provides up to 1000 wattsa or up to 2000 wattsb of continuous utility grade, sine wave power derived from a battery bank. It is designed to handle loads such as microwave ovens, TVs, DVD/Blu-ray players, and power tools. In addition, the Freedom Xi’s high-surge capability lets you handle many hard-to-start loads, including large TVs and small refrigerators.
Freedom XI Owners Guide.book Page 3 Friday, September 18, 2015 2:57 PM Over temperature Alarm and Shutdown During inverter mode, the Freedom Xi automatically alerts you if it is overheating and approaching the over-temperature shutdown limit. The Freedom Xi automatically shuts down when the limit is exceeded. Introduction Inverter Power Save The Freedom Xi has the ability to automatically turn off after 25 hours of continued operation of loads that are under 50 watts.
Freedom XI Owners Guide.book Page 4 Friday, September 18, 2015 2:57 PM Features Table 1 lists the default settings for the Freedom Xi system. Front Panel (All Models) You may record your settings in the right-hand column after you have configured the Freedom Xi.
Freedom XI Owners Guide.book Page 5 Friday, September 18, 2015 2:57 PM Features Rear Panel (All Models) 2 Display Panel (All Models) 3 3 1 2 4 1 4 Freedom Xi 1000 shown Feature Description 1 Negative DC cabling terminal connects to the negative terminal of the battery using a battery cable. 2 Ventilation grille (openings) must not be obstructed for the proper operation of the cooling fan and inverter. When the inverter is mounted, the ventilation grille must not point up or down.
Freedom XI Owners Guide.book Page 6 Friday, September 18, 2015 2:57 PM Features Side Panel 2 1 3 Feature 1 Description 20 A supplementary protector (PN: 807-2000) provides overload protection for the GFCI receptacles. In a hard wired installation, the supplementary protector does not protect output wiring. 15 A supplementary protector (PN: 807-1000) provides overload protection for the GFCI receptacles. In a hard wired installation, the supplementary protector does not protect output wiring.
Freedom XI Owners Guide.book Page 7 Friday, September 18, 2015 2:57 PM Freedom Inverter Configuration Viewing Inverter Information The LED screen displays Inverter information as well as feature settings in coordination with the LED lights underneath the screen. ◆ Press the Select button to toggle between the following basic information: Info and Setting LED Screen Info and Settings LED Battery Voltage .
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page 9 Friday, September 18, 2015 2:57 PM Freedom Inverter Configuration 4. 5. Continue pressing the Select button to cycle through the three settings – “”, “”, and “” until you reach the desired setting. Press and hold the Select button for five seconds to make the setting permanent. NOTE: Inverter mode ON (“”) will put the inverter on standby with the power save feature.
Freedom XI Owners Guide.book Page 10 Friday, September 18, 2015 2:57 PM Freedom Inverter Configuration To adjust the low battery shutdown setting: To return all feature settings to factory default settings: By default the low battery shutdown voltage setting is set to Low (“”). 1. Press and hold the Inverter Power button for five seconds. 2. Press the Inverter Power button until the LED screen flashes “” intermittently. 3.
Freedom XI Owners Guide.book Page 11 Friday, September 18, 2015 2:57 PM Freedom Inverter Operation Display Panel Operation The Freedom Xi features a display panel with three-digit LED display to show inverter, AC source, and battery status information. 1 2 3 4 Feature 1 See NOTE in Feature # 4. Description Inverter Power button • Press and hold for one second to turn the Freedom Xi’s inverter operation ON or OFF (when AC Shore Power is NOT present).
Freedom XI Owners Guide.book Page 12 Friday, September 18, 2015 2:57 PM Freedom Inverter Operation Feature 4 Description Select button • During inverter operation, press the button to choose what appears in the three-digit LED display: Battery Voltage, Battery Current, or Output Power. See “To change the inverter mode setting:” on page 8. NOTE: A corresponding LED lights up for each of the three items.
Freedom XI Owners Guide.book Page 13 Friday, September 18, 2015 2:57 PM Operating in Shore Power Mode The Freedom Xi operates in shore power mode when an AC source (a generator or utility power) is present at the AC input terminals. When the AC source is within operating range, the Freedom Xi unit bypasses inverter mode and powers the appliances connected to the unit. See “Transitioning from Inverter Mode to Shore Power” on page 17.
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page 15 Friday, September 18, 2015 2:57 PM Status LED During Inverter Operation Operating in Inverter Mode Table 2 Status LED during Inverter Operation The following summarizes the behavior of the Status LED during Inverter operation. Status LED Table 2 Status LED during Inverter Operation Solid RED through Fault condition detected and AC output power is not available. For details, see Table 3, “Error Codes Displayed on the Display Panel Screen” on page 24.
Freedom XI Owners Guide.book Page 16 Friday, September 18, 2015 2:57 PM Operating in Inverter Mode Checking Battery Status Turning the Audible Alarm ON or OFF During inverter operation, you can check the battery status by pressing the Select button until the Battery Voltage LED (or Battery Current LED) illuminates. The battery voltage (or battery current) appears in the three-digit LED display screen when the Battery Voltage LED (or Battery Current LED) illuminates.
Freedom XI Owners Guide.book Page 17 Friday, September 18, 2015 2:57 PM Operating During Transition Between Shore Power and Inverter Mode The Freedom Xi’s advanced power management is capable of transitioning power from an AC source to DC source within a fraction of a second and vice-versa. The Freedom Xi automatically detects when shore power is present and when it becomes unavailable or drops to less than 90 volts AC.
Freedom XI Owners Guide.book Page 18 Friday, September 18, 2015 2:57 PM Operating During Transition Between Shore Power and Inverter Mode Operating Limits Power Output Input Voltage The Freedom Xi can deliver up to 1000 watts or 2000 watts of continuous utility grade sine wave AC power. The wattage rating applies to resistive loads such as incandescent lights.
Freedom XI Owners Guide.book Page 19 Friday, September 18, 2015 2:57 PM Operating During Transition Between Shore Power and Inverter Mode Overload Conditions Over-temperature Conditions There are two kinds of overload conditions: During inverter operation, when the Freedom Xi’s internal temperature starts to approach its preset shutdown limit, the alarm will beep every two seconds and the display will show fault code .
Freedom XI Owners Guide.book Page 20 Friday, September 18, 2015 2:57 PM Operating During Transition Between Shore Power and Inverter Mode Routine Maintenance Freedom Xi Unit Minimal maintenance is required to keep your Freedom Xi operating properly. Periodically you should: • • • 20 Clean the exterior of the unit with a damp cloth to prevent the accumulation of dust and dirt. Ensure that the DC cables are secure and fasteners are tight. Make sure the ventilation openings are not clogged.
Freedom XI Owners Guide.book Page 21 Friday, September 18, 2015 2:57 PM Invert Power Derating vs. Ambient Temperature If the unit is in inverter mode and in elevated ambient temperature above 25 °C, you will have to reduce power draw according to the following chart to avoid over-temperature shutdown. watts 2000 watts 1000 Freedom XI 1000 1900 watts @12.5 volts 1800 watts 1800 1600 30°C @12.
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page 23 Friday, September 18, 2015 2:57 PM Troubleshooting • WARNING ELECTRICAL SHOCK HAZARD Do not disassemble the Freedom Xi. It does not contain any userserviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. Failure to follow these instructions can result in death or serious injury. 3. IMPORTANT: To obtain service go to “Contact Information” on page i.
Freedom XI Owners Guide.book Page 24 Friday, September 18, 2015 2:57 PM Warning Messages Warning messages in the form of audible alarms and error codes that appear on the display panel screen to alert you to an impending system change. Warnings do not affect operation. The error codes are listed in Table 3 below. The text in the Error Code column appears on the display screen of the display panel.
Freedom XI Owners Guide.book Page 25 Friday, September 18, 2015 2:57 PM Warning Messages Table 3 Error Codes Displayed on the Display Panel Screen Error Code Condition Mode Action Low battery voltage detected Inverting depending on setting, see “Operating Limits” on page 18. • • • Check battery status and recharge if necessary. Check for proper DC cable sizing. Check for loose connections and tighten if necessary.
Freedom XI Owners Guide.book Page 26 Friday, September 18, 2015 2:57 PM Troubleshooting Reference WARNING ELECTRICAL SHOCK HAZARD Do not disassemble the Freedom Xi. It does not contain any userserviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. Failure to follow these instructions can result in death or serious injury. Table 4 Troubleshooting Reference Problem Possible Cause Solution Alarm does not sound when an error is encountered.
Freedom XI Owners Guide.book Page 27 Friday, September 18, 2015 2:57 PM Troubleshooting Reference Table 4 Troubleshooting Reference Problem Possible Cause Solution No output voltage. The status LED is red. AC shore power is not available or out of operating range and the inverter has shut down with the display screen showing one of the following error codes: • Low input voltage (fault code ) • High input voltage (fault code ) • • Verify the unit is connected to a 12V battery.
Freedom XI Owners Guide.book Page 28 Friday, September 18, 2015 2:57 PM Troubleshooting Reference Table 4 Troubleshooting Reference Problem Possible Cause Solution No output voltage. The Status LED is green or yellow. GFCI has tripped or supplementary breaker has tripped. Check load and reset the GFCI or supplementary breaker. Circuit breaker on the AC load panel or Reset the circuit breaker or check the AC output disconnect AC output disconnect has tripped. circuits. No output voltage.
Freedom XI Owners Guide.book Page 29 Friday, September 18, 2015 2:57 PM Troubleshooting Reference Table 4 Troubleshooting Reference Problem Possible Cause No output voltage. The status LED is not lighting up. The jumper wire on the power module Ensure the jumper wire is installed if the ignition control feature panel connecting the “Ignition Control” is not in use. If the ignition control feature is in use, ensure the and “Disabled” terminals is removed vehicle’s ignition is on.
Freedom XI Owners Guide.book Page 30 Friday, September 18, 2015 2:57 PM Inverter Applications The Freedom Xi performs differently depending on the AC loads connected to it. If you are having problems with any of your loads, read this section. Resistive Loads These are the loads that the inverter finds the simplest and most efficient to drive. Voltage and current are in phase (that is, in step with one another). Resistive loads usually generate heat in order to accomplish their tasks.
Freedom XI Owners Guide.book Page 31 Friday, September 18, 2015 2:57 PM Specifications NOTE: Specifications are subject to change without prior notice. Physical Specifications Freedom Xi 1000 Freedom Xi 2000 L×W×H 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) Net Weight 11 lbs (5 kg) 14.4 lbs (6.
Freedom XI Owners Guide.book Page 32 Friday, September 18, 2015 2:57 PM Specifications DC Input Freedom Xi 1000 Freedom Xi 2000 10.5–16.5 VDC (low limit) 11.8–16.5 VDC (mid limit) 12.1–16.5 VDC (high limit) 10.5–16.5 VDC (low limit) 11.8–16.5 VDC (mid limit) 12.1–16.5 VDC (high limit) Safe non-operating voltage range 0–24 VDC 0–24 VDC Nominal voltage for all models 12.5 VDC 12.
Freedom XI Owners Guide.
Freedom XI Owners Guide.book Page ii Friday, September 18, 2015 2:57 PM Schneider Electric Solar Inverters USA Inc. +1 800 670 0707 +1 408 987 6030 www.xantrex.