User Manual

975-0754-01-01 3
Introduction
Over temperature Alarm and Shutdown During inverter mode,
the Freedom Xi automatically alerts you if it is overheating and
approaching the over-temperature shutdown limit.
The Freedom Xi automatically shuts down when the limit is
exceeded.
Low Power Consumption When the Freedom Xi is inverting
without a load, it draws less than 0.6
amp of current from the battery
(or battery bank).
This feature allows the unit to operate without draining too much
stored energy.
Selectable Low Battery Shutdown The low battery shutdown
for the inverter can be manually selected by the user by choosing a
low (10.5
V), middle (11.8 V), or high (12.1 V) setting.
Ignition Control The Freedom HFS provide two user-selectable
ignition control method:
Ignition Lockout: The Freedom Xi features the ability to
inhibit the inverter from operating in the absence of a
voltage signal from a vehicle's ignition circuit. This is
particularly useful if the inverter is required to operate only
when a vehicle's engine is running.
Ignition Auto-on: The Freedom Xi can automatically turn
the inverter on and off with the vehicle's ignition circuit.
Inverter Power Save The Freedom Xi has the ability to
automatically turn off after 25 hours of continued operation of loads
that are under 50
watts. It is designed to, in conjunction with LBCO,
to prevent the battery from deep discharge.
Freedom XI Owners Guide.book Page 3 Friday, September 18, 2015 2:57 PM