User Manual

16 Freedom Xi Owners Guide
Operating in Inverter Mode
Checking Battery Status
During inverter operation, you can check the battery status by
pressing the Select button until the Battery Voltage LED (or Battery
Current LED) illuminates. The battery voltage (or battery current)
appears in the three-digit LED display screen when the Battery
Voltage LED (or Battery Current LED) illuminates.
The normal operating battery voltage range is between 11 and
15 volts.
Checking Output Power
During inverter operation, you can check how much power
(displayed in kW) the Freedom Xi is supplying to the connected
loads by pressing the Select button until the Output Power LED
illuminates.
Operating Several Loads at Once
If you are going to operate several loads from the Freedom Xi, turn
them on one at a time after you have turned the inverter on.
Turning loads on separately helps to ens
ure that the inverter does
not have to deliver the starting current for all the loads at once, and
will help prevent an overload shutdown.
Turning the Audible Alarm ON or OFF
The Freedom Xi’s audible alarm can be turned ON or OFF. See “To
adjust the alarm setting:” on page 9.
Any warnings such as fault conditions or imminent shutdown are
bo
th displayed on the display panel’s screen and sounded on the
alarm speakers.
It is not possible to turn OFF the screen and
prevent it from
displaying error codes but it is possible to turn OFF the audible
alarm.
NOTE: The alarm setting will reset to its default setting when the
Freedom Xi’s Inverter Power button is turned OFF then turned ON
again.
Freedom XI Owners Guide.book Page 16 Friday, September 18, 2015 2:57 PM