Operating During Transition Between Shore Power and Inverter Mode
The Freedom Xi’s advanced power management is capable of
transitioning power from an AC source to DC source within a
fraction of a second and vice-versa.
The Freedom Xi automatically detects when shore power is present
and when it becomes unavailable or drops to less than 90
volts AC.
Transitioning from Shore Power to Inverter
Mode
When the unit is operating in shore power mode and shore power is
lost, the Freedom Xi has less than 40 milliseconds to switch to
operating in inverter mode and start drawing power from the
battery.
The Status LED will turn from solid (or flashing) GREEN to a solid
YELLOW.
Transitioning from Inverter Mode to Shore
Power
When the unit is operating in inverter mode and shore power
becomes available, the Freedom Xi begins a 20-second countdown
to verify the stability of the shore power. If shore power remains
stable for a 20-second countdown, at the end of the countdown, the
Freedom Xi will switch to shore power mode within
40
milliseconds and start drawing power from the AC source.
The Status LED will turn from solid YELLOW to flashing
YELLOW during the 20-second countdown, then turn to GREEN
when battery power is transitioned successfully to shore power.