Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 151
Incompatible Functions
The following function will be inaccessible or deactivated after an Automatic restart.
This is only possible for control type if [2/3 wire control] (tCC) is set to [2 wire] (2C) and if [2 wire type]
(tCt) is set to [Level] (LEL) or [Fwd priority] (PFO). See [2/3 wire control] (tCC) page 73.
The [1.2 MONITORING] (MOn-) menu page 41
can be used to display the functions assigned to each input
in order to check their compatibility.
When a function is assigned, a appears on the graphic display terminal, as illustrated in the example below:
If you attempt to assign a function that is incompatible with another function that has already been assigned,
an alarm message will appear:
With the graphic display terminal:
With the integrated display terminal and the remote display terminal:
COMP flashes until ENT or ESC is pressed.
When you assign a logic input, an analog input, a reference channel or a bit to a function, pressing the HELP
key will display the functions that may already have been activated by this input, bit or channel.
When a logic input, an analog input, a reference channel or a bit that has already been assigned is assigned
to another function, the following screens appear:
With the graphic display terminal:
If the access level permits this new assignment, pressing ENT confirms the assignment.
If the access level does not permit this new assignment, pressing ENT results in the following display:
With the integrated display terminal:
The code for the first function, which is already assigned, is displayed flashing.
If the access level permits this new assignment, pressing ENT confirms the assignment.
If the access level does not permit this new assignment, pressing ENT has no effect, and the message
continues to flash. It is only possible to exit by pressing ESC.
RDY Term 0.0Hz 0A
APPLICATION FUNCT.
REFERENCE SWITCH.
REF. OPERATIONS
RAMP
STOP CONFIGURATION
AUTO DC INJECTION
Code << >> Quick
RDY Term +0.0 Hz 0.0 A
INCOMPATIBILITY
The function can't be assigned
because an incompatible
function is already selected. See
programming book.
ENT or ESC to continue
RUN Term 0.0 Hz 0.0 A
WARNING - ASSIGNED TO
Forward
ENT-Valid. ESC-Abort
RUN Term 0.0 Hz 0.0 A
ASSIGNMENT FORBIDDEN
Un-assign the present
functions, or select
"Advanced" access level
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com