Configuration Mode (ConF)
S1A28692 03/2010 177
Brake logic control, horizontal movement in open-loop mode
Key:
(bEn): [Brake engage freq]
(bEt): [Brake engage time]
(brt): [Brake Release time]
(Ibr): [Brake release I FW]
(SdC1): [Auto DC inj. level 1]
(tbE): [Brake engage delay]
(ttr): [Time to restart]
Frequency
Reference
bEn
t
Flux current
Rated flux
current
SdC1
Torque current
Ibr
Direction of
operation
ReverseForward
Relay
or logic
output
Brake contact
State of brake
Engaged
Released
Type of motor
control
Flux
brt
ttrbEttbE
Frequency
Torque
Injection
Locking
0
t
t
t
t
t
t
Fluxed motor
Ibr attained
0 attained