Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 181
Parameters described in this page can be accessed by:
(1) The parameter can also be accessed in the [SETTINGS] (SEt-) menu.
(2) In corresponds to the rated drive current indicated in the Installation manual and on the drive nameplate.
JdC [Jump at reversal]
[Auto] (AUtO) to 10 Hz [Auto] (AUtO)
g
T
(1)
This parameter can be accessed if [Movement type] (bSt) page 179
is set to [Hoisting] (UEr).
AUtO
-
[Auto] (AUtO): The drive takes a value equal to the rated slip of the motor, calculated using the drive parameters
0 to 10 Hz: Manual control
When the reference direction is reversed, this parameter can be used to avoid loss of torque (and consequential release of load)
on transition to zero speed. Parameter is not applicable if [Engage at reversal] (bEd) = [Yes] (YES).
ttr [Time to restart]
0.00 to 15.00 s 0 s
g
T
(1)
Time between the end of a brake engage sequence and the start of a brake release sequence.
Code Name / Description Adjustment range Factory setting
g
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
T
Parameter that can be modified during operation or when stopped.
DRI- > CONF > FULL > FUN- > BLC-