Installation manual

Configuration Mode (ConF)
182 S1A28692 03/2010
Parameters described in this page can be accessed by:
Brake control logic expert parameters
Following parameters for brake logic sequence are accessible in expert mode only.
Code Name / Description Adjustment range Factory setting
brH0 [BRH b0]
0
g
Selection of the brake restart sequence if a run command is repeated while the brake is engaging.
0
1
[0] (0): The engage/release sequence is completely executed
[1] (1): The brake is released immediately
A run command may be requested during the brake engagement phase. Whether or not the brake release sequence is executed
depends on the value selected for [BRH b0] (brH0).
Note: If a run command is requested during the "ttr" phase, the complete brake control sequence is initialized.
brH1 [BRH b1]
0
g
Deactivation of the brake contact in steady state fault.
0
1
[0] (0): The brake contact in steady state fault is active (fault state if the contact is open during operation). The
[Brake feedback] (brF) brake contact fault is monitored in all operating phases.
[1] (1): The brake contact in steady state fault is inactive. The [Brake feedback] (brF) brake contact fault is only monitored
during the brake release and engage phases.
Frequency
Run command
Relay or
logic input
Frequency
Relay or
logic input
bEn
[BRH b0]
(brH0) = 1
[BRH b0] (brH0) = 0
DRI- > CONF > FULL > FUN- > BLC-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com