Installation manual

Configuration Mode (ConF)
184 S1A28692 03/2010
EXTERNAL WEIGHT MEASUREMENT
Load measurement
This function uses the information supplied by a weight sensor to adapt the current
[Brake release I FW] (Ibr) of the [BRAKE LOGIC CONTROL] (bLC-) function. The signal from the
weight sensor can be assigned to an analog input (usually a 4 - 20 mA signal) or to the pulse-in input,
according to the type of weight sensor.
Example: Measurement of the total weight of a hoisting winch and its load
The current [Brake release I FW] (Ibr) is adapted in accordance with the curve below.
Weight sensor
signal
100%
[Point 2x]
LP2
Zero load
[Point 1x]
LP1
Ibr
[Point 2y]
(CP2)
[Point 1y]
(CP1)
0
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com