Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 185
Parameters described in this page can be accessed by:
(1) In corresponds to the rated drive current indicated in the Installation manual and on the drive nameplate.
Code Name / Description Adjustment range Factory setting
FUn- [APPLICATION FUNCT.] (continued)
ELM- [EXTERNAL WEIGHT MEAS.]
PES [Weight sensor ass.]
[No] (nO)
WARNING
LOSS OF CONTROL
Check that [Point 1 X] (LP1), [Point 2x] (LP2), [Point 1Y] (CP1) and [Point 2Y] (CP2) are correctly
set to avoid loss of control of the load being lifted.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
nO
A11
A12
A13
PI
AIU1
AIU2
OA01
...
OA10
This parameter can be configured if [BRAKE LOGIC CONTROL] (bLC-) page 179
is not set to [No] (nO).
[No] (nO): Not assigned
[Al1] (A11): Analog input A1
[Al2] (A12): Analog input A2
[Al3] (A13): Analog input A3
[RP] (PI): Pulse input
[AI virtual 1] (AIU1): Virtual analog input 1 with the jog dial
[AI virtual 2] (AIU2): Virtual analog input 2 by the communication bus
[OA01] (OA01): Function blocks: Analog Output 01
...
[OA10] (OA10): Function blocks: Analog Output 10
LP1 [Point 1 X]
0 to LP2-0.01% 0%
g
0 to 99.99% of signal on assigned input.
[Point 1x] (LP1) must be less than [Point 2x] (LP2).
This parameter can be accessed if [Weight sensor ass.] (PES) is assigned.
CP1 [Point 1Y]
-1.36 In to 1.36 In (1) -In (1)
g
Current corresponding to load [Point 1 X] (LP1), in A.
This parameter can be accessed if [Weight sensor ass.] (PES) is assigned.
LP2 [Point 2X]
LP1+0.01% to 100% 50%
g
0.01 to 100% of signal on assigned input.
[Point 2x] (LP2) must be greater than [Point 1x] (LP1).
This parameter can be accessed if [Weight sensor ass.] (PES) is assigned.
CP2 [Point 2Y]
-1.36 In to 1.36 In (1) 0 A
g
Current corresponding to load [Point 2x] (LP2), in A.
This parameter can be accessed if [Weight sensor ass.] (PES) is assigned.
IbrA [Ibr 4-20 mA loss]
0 to 1.36 In (1) 0
g
T
Brake release current in the event of the loss of the weight sensor information.
This parameter can be accessed if the weight sensor is assigned to an analog current input and the 4-20 mA loss is deactivated.
Recommended settings: Rated motor current for a hoisting application.
g
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
T
Parameter that can be modified during operation or when stopped.
DRI- > CONF > FULL > FUN- > ELM-