TORQUE LIMITATION
There are two types of torque limitation:
With a value that is fixed by a parameter
With a value that is set by an analog input (AI or pulse)
If both types are enabled, the lowest value is taken into account. The two types of limitation can be configured
or switched remotely using a logic input or via the communication bus.
[Yes]
(YES)
LI
[Motoring torque
lim] (tLIM)
[Gen. torque lim]
(tLIG)
Torque
limitation via
parameter
[Torque limit. activ.] (tLA)
[No]
(nO)
[LI]
[Yes]
(YES)
LI
[AI.] (AI.)
[RP] (PI)
Torque
limitation via
analog input,
RP
[Analog limit. act.] (tLC)
[No]
(nO)
[LI]
Lowest value
taken into account
Limitation
value
[Torque ref. assign.] (tAA)