Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 209
POSITIONING BY SENSORS
This function is used for managing positioning using position sensors or limit switches linked to logic inputs or
using control word bits:
Slowing down
Stopping
The action logic for the inputs and bits can be configured on a rising edge (change from 0 to 1) or a falling edge
(change from 1 to 0). The example below has been configured on a rising edge:
The slowdown mode and stop mode can be configured.
The operation is identical for both directions of operation. Slowdown and stopping operate according to the
same logic, described below.
Forward run command
Reverse run command
[Slowdown forward]
[Stop FW limit sw.]
Speed
[Low speed]
(LSP)
0
0
0
0
0
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com