Installation manual

Configuration Mode (ConF)
212 S1A28692 03/2010
Parameters described in this page can be accessed by:
Code Name / Description Adjustment range Factory setting
FUn- [APPLICATION FUNCT.] (continued)
LPO- [POSITIONING BY SENSORS]
Note: This function cannot be used with certain other functions. Follow the instructions on page 148.
SAF [Stop FW limit sw.]
[No] (nO)
nO
LI1
...
Stop switch forward.
[No] (nO): Not assigned
[LI1] (LI1): Logical input LI1
[...] (...): See the assignment conditions on page 138
SAr [Stop RV limit sw.]
[No] (nO)
Stop switch reverse.
Identical to [Stop FW limit sw.] (SAF) above.
SAL [Stop limit config.]
[Active low] (LO)
g
WARNING
LOSS OF CONTROL
If [Stop limit config.] (SAL) is set to [Active high] (HIG), the stop command will be activated on active
signal (stop order will not be given if signal is not applied for any reason).
Do not select [Active high] (HIG) unless you are sure that your signal will be present in any case.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
LO
HIG
Level stop switch activation.
This parameter can be accessed if at least one limit switch or one stop sensor has been assigned. It defines the positive or
negative logic of the bits or inputs assigned to the stop.
[Active low] (LO): Stop controlled on a falling edge (change from 1 to 0) of the assigned bits or inputs
[Active high] (HIG): Stop controlled on a rising edge (change from 0 to 1) of the assigned bits or inputs
dAF [Slowdown forward]
[No] (nO)
Slowdown attained forward.
Identical to [Stop FW limit sw.] (SAF) above.
dAr [Slowdown reverse]
[No] (nO)
Slowdown attained reverse.
Identical to [Stop FW limit sw.] (SAF) above.
dAL [Slowdown limit cfg.]
[Active low] (LO)
g
CAUTION
RISK OF DAMAGE TO THE EQUIPMENT
If [Slowdown limit cfg.] (dAL) is set to [Active high] (HIG), the slowdown command will be activated on
active signal (slowdown order will not be given if signal is not applied for any reason).
Do not select [Active high] (HIG) unless you are sure that your signal will be present in any case.
Failure to follow these instructions can result in equipment damage.
LO
HIG
This parameter can be accessed if at least one limit switch or one slowdown sensor has been assigned. It defines the positive
or negative logic of the bits or inputs assigned to the slowdown.
[Active low] (LO): Slowdown controlled on a falling edge (change from 1 to 0) of the assigned bits or inputs
[Active high] (HIG): Slowdown controlled on a rising edge (change from 0 to 1) of the assigned bits or inputs
DRI- > CONF > FULL > FUN- > LPO-