Installation manual

Configuration Mode (ConF)
226 S1A28692 03/2010
Connection of synchronization I/O
The starting conditions for the function are:
Base speeds reached on both drives
[Yarn control] (trC) input activated
Synchronization signal present
Note: The [Quick step High] (qSH) and [Quick step Low] (qSL) parameters should generally be kept at
0.
t
t
t
t
t
trH
trL
trH
trL
Traverse control
command on master
and slave
Run command on
master and slave
Yarn guide motor
speed
(master drive)
tSY/SnC synchronization
Winding motor speed
(slave drive)
(SnCO) LOp
COM
LIp (SnCI)
COM
ATV32 ATV32
Master drive Slave drive
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com