Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 227
Parameters described in this page can be accessed by:
Code Name / Description Adjustment range Factory setting
FUn- [APPLICATION FUNCT.] (continued)
tr0- [TRAVERSE CONTROL]
Note: This function cannot be used with certain other functions. Follow the instructions on page 148.
trC [Yarn control]
[No] (nO)
nO
LI1
...
The Traverse control cycle starts when the assigned input or bit changes to 1 and stops when it changes to 0.
[No] (nO):
Function inactive, thereby helping to prevent access to other parameters
[LI1] (LI1): Logical input LI1
[...] (...): See the assignment conditions on page 138
trH [Traverse freq. high]
0 to 10 Hz 4 Hz
g
T
(1)
Traverse frequency high.
trL [Traverse Freq. Low]
0 to 10 Hz 4 Hz
g
T
(1)
Traverse frequency low.
qSH [Quick step High]
0 to [Traverse freq. high] (trH) 0 Hz
g
T
(1)
Quick step high.
qSL [Quick step Low]
0 to [Traverse Freq. Low] (trL) 0 Hz
g
T
(1)
Quick step low.
tUP [Traverse ctrl. accel.]
0.1 to 999.9 s 4 s
g
T
Acceleration traverse control.
tdn [Traverse ctrl. decel]
0.1 to 999.9 s 4 s
g
T
Deceleration traverse control.
tbO [Reel time]
0 to 9,999 min 0 min
g
T
Reel execution time.
EbO [End reel]
[No] (nO)
g
The assigned output or relay changes to state 1 when the traverse control operating time reaches the [Reel time] (tbO).
nO
LO1
r2
dO1
[No] (nO): Not assigned
[LO1] (LO1): Logical output LO1
[R2] (r2): Relay R2
[dO1] (dO1): Analog output AO1 functioning as a logic output. Selection can be made if [AO1 assignment] (AO1) page 129
is set to [No] (nO).
DRI- > CONF > FULL > FUN- > TRO-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com