Installation manual

Monitoring Mode (MOn)
42 S1A28692 03/2010
Introduction
The parameters can be accessed when the drive is running or stopped.
Some functions have numerous parameters. In order to clarify programming and avoid having to scroll through
endless parameters, these functions have been grouped in submenus. Like menus, submenus are identified
by a dash after their code.
When the drive is running, the value displayed is one of the monitoring parameters. By default, the value
displayed is the input frequency reference ([Frequency ref.] (FrH) parameter page 44
).
While the value of the new monitoring parameter required is being displayed, press a second time on the jog
dial key to display the units or press and hold down the jog dial (ENT) again (for 2 seconds) to confirm the
change of monitoring parameter and store it. From then on, it is the value of this parameter that will be
displayed during operation (even after powering down).
Unless the new choice is confirmed by pressing and holding down ENT again, the display will revert to the
previous parameter after powering down.
Note: After the drive has been turned off or following a loss of line supply, the parameter displayed is the drive
status (example: [Ready] (rdY)). The selected parameter is displayed following a run command.