Installation manual

Configuration Mode (ConF)
S1A28692 03/2010 69
Parameters described in this page can be accessed by:
Factory Settings
Code Name / Description Factory setting
COnF [1.3 CONFIGURATION]
FCS- [FACTORY SETTINGS]
FCSI [Config. Source]
[Macro-Conf] (InI)
g
Choice of source configuration.
If the configuration switching function is configured, it will not be possible to access [Config 1] (CFG1) and
[Config 2] (CFG2).
Note: To load the drive's presettings previously memorized ([Config 1] (Str 1) or [Config 2] (Str2)), select the source
configuration [Config. Source] (FCSI) = [Config 1] (CFG1) or [Config 2] (CFG2) followed by a factory setting
[Goto FACTORY SETTINGS] (GFS) = [YES] (YES).
InI
CFG1
CFG2
[Macro-Conf] (InI): Factory configuration, return to selected macro configuration
[Config 1] (CFG1): Configuration 1
[Config 2] (CFG2): Configuration 2
FrY- [PARAMETER GROUP LIST]
Selection of menus to be loaded.
See the multiple selection procedure on page 33
for the integrated display terminal and page 24 for the graphic display terminal.
Note: In factory configuration and after a return to "factory settings", [PARAMETER GROUP LIST] will be empty.
ALL
drM
MOt
COM
dIS
[All] (ALL): All parameters (the function blocks program will also be erased)
[Drive configuration] (drM): The [1 DRIVE MENU] (drI-) menu without [COMMUNICATION] (COM-). In the
[2.4 DISPLAY CONFIG.] menu, [Return std name] (GSP) page 271
returns to [No] (nO).
[Motor param] (MOt): Motor parameters, see page 279
.
The following selections can only be accessed if [Config. Source] (FCSI) is set to [Macro-Conf.] (InI).
[Comm. menu] (COM): The [COMMUNICATION] (COM-) menu without either [Scan. In1 address] (nMA1) to
[Scan. In8 address] (nMA8) or [Scan.Out1 address] (nCA1) to [Scan.Out8 address] (nCA8).
[Display config.] (dIS): The [3.3 MONITORING CONFIG.] (MCF-) menu
GFS [Goto FACTORY SETTINGS]
g
DANGER
UNINTENDED EQUIPMENT OPERATION
Check that the modification of the current configuration is compatible with the wiring diagram used.
Failure to follow these instructions will result in death or serious injury.
nO
YES
It is only possible to revert to the factory settings if at least one group of parameters has previously been selected.
[No] (nO): No
[Yes] (YES): The parameter changes back to [No] (nO) automatically as soon as the operation is complete
SCSI [Save config]
[No] (nO)
g
The active configuration to be saved does not appear for selection. For example, if it is [Config 0] (Str0), only
[Config 1] (Str1) and [Config 2] (Str2) appear. The parameter changes back to [No] (nO) as soon as the operation is
complete.
nO
Str0
Str1
Str2
[No] (nO): No
[Config 0] (Str0): Press and hold down the ENT key for 2 s
[Config 1] (Str1): Press and hold down the ENT key for 2 s
[Config 2] (Str2): Press and hold down the ENT key for 2 s
g
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
To change the assignment of this parameter, press the ENT key for 2 s.
2 s
2 s
DRI- > CONF > FCS-