Configuration Mode (ConF)
88 S1A28692 03/2010
Parameters described in this page can be accessed by:
Ibr [Brake release I FW]
0 to 1.36 In (1) 0.0 A
g
T
Brake release current threshold for lifting or forward movement. See page 179.
Ird [Brake release I Rev]
0 to 1.36 In (1) 0.0 A
g
T
Brake release current threshold for lowering or reverse movement. See page 179.
brt [Brake Release time]
0 to 5.00 s 0 s
g
T
Brake release time delay. See page 179.
bIr [Brake release freq]
[Auto] (AUtO)
0 to 10 Hz
[Auto] (AUtO)
g
T
See page 180.
AUtO [Auto] (AUtO): Nominal value
bEn [Brake engage freq]
[Auto] (AUtO)
0 to 10 Hz
[Auto] (AUtO)
g
T
Brake engage frequency threshold. See page 180.
tbE [Brake engage delay]
0 to 5.00 s 0 s
g
T
WARNING
LOSS OF CONTROL
Modify the Brake engage delay for horizontal movement only otherwise the control of the load can be lost.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Time delay before request to engage brake. See page 180.
bEt [Brake engage time]
0 to 5.00 s 0 s
g
T
Brake engage time (brake response time). See page 180.
JdC [Jump at reversal]
[Auto] (AUtO)
0 to 10 Hz
[Auto] (AUtO)
g
T
See page 181.
AUtO [Auto] (AUtO): Nominal value
ttr [Time to restart]
0.00 to 15.00 s 0.00 s
g
T
Time between the end of a brake engage sequence and the start of a brake release sequence. See page 181.
Code Name / Description Adjustment range Factory setting